16. Electrical Equipment
16-14
Secondary coil
Attached the spark plug cap, measure the
resistance between plug cap side and green
terminal.
Standard value: 7~12k (20°C)
Remove the spark plug cap, measure the
resistance between plug cap side and green
terminal.
Standard value: HU10U/W 3~5K±10% (20°C)
HU05U 4.0K±15% (20°C)
Secondary coil is good if resistance within
standard.
Secondary coil is broken if resistance is infinite. If
the spark plug cap attached and the measured
value exceeds standard value, it means the spark
plug cap is in not good.
Replacement
Remove the ignition coil bolt (2 screws) to replace
the ignition coil if necessary.
Pulse Generator
Caution
Checking pulse generator can be done on
engine. But, the spark plug must be installed
onto the cylinder head, and cylinder
compression pressure must be in normal
condition.
Check
Remove body cover.
Remove the pulse generator coupler.
Measure the resistance between blue/yellow
terminal on engine side and frame ground.
Standard: HU10U/W 50~200 (20°C)
HU05U 115±20% (20°C)
Replace the alternator if the measured value
exceeds standard value.
Exciting coil
Remove the exciting coil coupler.
Measure the resistance between black/red wire on
engine side and frame ground.
Standard: HU10U/W 400~800 (20°C)
HU05U 602±20%
Replace the alternator if the measured value
exceeds the standard value.
Ignition coil
To this chapter contents
193


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sym Mio 50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sym Mio 50 in the language / languages: English as an attachment in your email.

The manual is 7,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sym Mio 50

Sym Mio 50 User Manual - Dutch - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info