16. Electrical Equipment
16-12
CDI. Unit
Removal
Remove the battery cover.
Remove the CDI.
Inspection
Disconnect the coupler from the CDI unit.
Make the following inspection at each terminal of
the harness side coupler.
Standard (at 20)
ITEM Measure at:
HU10U/W HU05U
Main Switch Black/white-green Continuity as main switch OFF
Main Switch Black/ Blue -green Continuity (battery voltage) as master switch ON
Exciter Coil Black/Red-Green 400 ~800 115±20%
Pulse Generator Blue/Yellow-green 50 ~200 602±20%
Primary Black/yellow-green 0.21±10% 0.31±15%
Green-high voltage
cable -w/o Cap
3~5K 4.0 K±15%
Ignition Coil
Secondary
Green-high voltage
cable - w/ Cap
7~12K
CDI. Unit
CDI. Unit
To this chapter contents
191


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sym Mio 50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sym Mio 50 in the language / languages: English as an attachment in your email.

The manual is 7,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sym Mio 50

Sym Mio 50 User Manual - Dutch - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info