Technical Appendix
Legal Requirements
Before installation and/or use of this appliance please read these
instructions carefully to ensure that all requirements are fully
understood.
The appliance must be fitted by a registered installer*, or
approved by your local building control officer.
It is very important to understand the requirements of the national
Building Regulations and standards, along with any local
regulations and working practices that may apply. Should any
conflict occur between these instructions and these regulations
then the regulations must apply.
Your local Building Control Office can advise regarding the
requirements of the regulations.
Works must be carried out with care to meet the requirements of
Health and Safety and comply with the Health and Safety rules**,
and any new regulations introduced during the lifetime of these
instructions. Particular attention should be drawn to:
Handling: The appliance is heavy. Adequate facilities
must be available for loading, unloading and on site
handling.
Fire Cement: Some fire cement is caustic and must not
come into contact with the skin. Protective gloves must be
worn. Wash hands thoroughly with plenty of water after
contact with skin.
Asbestos: This appliance contains no asbestos. If there
is the possibility of disturbing any asbestos in the course of
installation seek specialist guidance and use appropriate
equipment.
Metal Parts: Take care when installing or servicing the
stove to avoid personal injury.
A faulty installation can cause danger to the inhabitants and
structure of the building.
For users of this appliance:
Your building insurance company may require you to inform them
that a new heating appliance has been installed on your property.
Check that your cover is still valid after installing the appliance.
1. Flue Outlet Positions
150mm
max
Vertical
Measurement
Terminal
Insulation
Flue
Horizontal
Measurement
Adjacent
Building
The datum for vertical measurement is the point
of discharge of the flue from either the point of
discharge of the flue or 150mm above insulation,
whichever is the lower.
IMPORTANT: Seek specialist advice if
installing in a dwelling with a thatched roof
These positions are defined by Document J of the Building Regulations.
Adjacent Building
Point where the flue passes through weather surface
(Notes 1 & 2)
Clearances to flue outlet
A
At or within 600mm of the ridge At least 600mm above ridge
B
Elsewhere on roof (whether pitched or flat) At least 2300mm horizontally from the nearest point on the weather surface and:
a) at least 1000mm above highest point of intersection of the chimney with and the weather surface; or
b) at least as high as the ridge
C
Below (on a pitched roof) or within 2300mm horizontally to
openable rooflight, dormer window, or other opening (Note
3)
At least 1000mm above the top of opening
D
Within 2300mm of an adjoining or adjacent building,
whether or not beyond the boundary (Note 3)
At least 600mm above any part of the adjacent of building within 2300mm
1) The weather surface is the building external surface, such as it's roof tiles or external walls.
2) A flat roof has a pitch less than 10°.
3) The clearance given for A or B, as appropriate, will also apply.
4) A vertical flue fixed to an outside wall should be treated as equivalent to an inside flue emerging at the nearest edge of the roof.
England and Wales – Document J / Scotland - Part
F/Document J (Republic of Ireland only)
the latest edition of BS 8303, BS EN 15287, BS 7566
*Registered on the Competent Persons Scheme
(GB only) see page 35/ INFO (Republic of Ireland).
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stovax Riva Vision - Wood Freestanding Stove at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stovax Riva Vision - Wood Freestanding Stove in the language / languages: English as an attachment in your email.

The manual is 4.91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info