593142
8
Zoom out
Zoom in
Previous page
1/27
Next page
- 14 - - 15 -
L Disconnect the power supply before
attempting any work on the sensor!
L During installation, the electrical wiring you
are connecting must be dead.
Therefore, switch off the power first and use
a voltage tester to make sure the wiring is off
circuit.
L Follow safety regulations!
L Observe the general installation conditions.
L Installing the sensor involves work on the
mains power supply.
This work must therefore be carried out pro-
fessionally in accordance with national wiring
regulations and electrical operating condi-
tions.
L Only select time and twilight setting with the
lens in place.
HBS 300 Highbay / HBS 200 Highbay package contents
L Sensor HBS 300 Highbay or HBS 200
Highbay or RHB 300-EU or RHB 200-EU or
RM 50 Highbay or MF1
L Two 1/2" locknuts
L Installation instructions
Operating Instructions
GB
Safety precautions
HBS 300 Highbay / HBS 200 Highbay installation summary
Needed for installation
L 3 connection terminals
Applications
L HBS 300 Highbay: open areas where 360
degree coverage is needed, such as ware-
houses, distribution centres, sports halls
L HBS 200 Highbay: aisles in high-bay
warehouses
Intended uses
L Suitable for indoor use only
L For customised lighting control
HBS 300 Highbay / HBS 200 Highbay product summary
HBS 300 Highbay / HBS 200 Highbay sensors
provide effective lighting control for applications
in high, open areas, such as warehouses.
The sensors are fitted with three pyroelectric
dual-element detectors and are suitable for a
wide range of installation heights of up to 12 m.
They can be fitted directly to a high-mounted
luminaire or junction box.
Product description
Technical Specifications
HBS 200 Highbay
99 x 99 x 69.1 mm
Connector length 15.75 mm
120-240V~, 50/60Hz
1200 W max.
at least 2.5 m - 14 m
15 sec. - 30 min.
2 - 2000 lux
Aisle
30 x 4 m
IP20
II
-20 °C to +50 °C
Dimensions:
Mains voltage:
Output:
Installation height:
Time setting:
Twilight setting:
Detection zone:
Reach:
IP rating:
Protection class:
Temperature range
HBS 300 Highbay
99 x 99 x 66 mm
Connector length 15.75 mm
120-240V~, 50/60Hz
1200 W max.
at least 2.5 m - 14 m
15 sec. - 30 min.
2 - 2000 lux
360°
up to 18 m
IP20
II
-20 °C to +50 °C
System Components
HBS 300 Highbay
a
1/2" threaded connector
b Lock nuts
c DIP switch for setting stay-ON time
d Light-level potentiometer
e Detection lens
HBS 200 Highbay
a
1/2" threaded connector
b Lock nuts
c DIP switch for setting stay-ON time
d Light-level potentiometer
e Detection lens
The HBS 200 Highbay covers an aisle of up
to 30 m in length when installed at a height
of 12 m.
1
GB
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steinel RM 50 Highbay at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steinel RM 50 Highbay in the language / languages: English, German, French, Portuguese, Swedish, Spanish as an attachment in your email.

The manual is 2,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info