Functional Warranty
This STEINEL product has been manufactured with
great care, tested for proper operation and safety
in accordance with applicable regulations and then
subjected to random sample inspection. STEINEL
guarantees that it is in perfect condition and proper
working order. The warranty period is 36 months,
starting from the date of sale to the consumer.
We will remedy defects caused by material flaws or
manufacturing faults. The warranty will be met by
repair or replacement of defective parts at our own
discretion. The warranty does not cover damage to
wear parts, nor does it cover damage or defects
caused by improper treatment, maintenance or the
use of non-genuine parts. Further consequential
damage to other objects shall be excluded.
Claims under the warranty will only be accepted if
the product is sent fully assembled and well packed
complete with a brief description of the fault as well
as a receipt or invoice (date of purchase and dealer's
stamp) to the appropriate Service Centre.
Repair Service:
Please ask your nearest service
centre how to proceed for repairing
faults not covered by the warranty or
occurring after the warranty expires.
SensorLight switches ON
when it should not
Change in SensorLight reach
Red LED flashing rapidly
Wind is moving trees and bush-
es in the detection zone
Cars in the street are detected
Sudden temperature changes
due to weather (wind, rain, snow)
or exhaust air from fans or open
windows
Change detection zone
Change detection zone
Adjust detection zone or
install in a different place
Differing ambient temperatures Use shrouds to define
detection zone precisely
Internal fuse activated Switch SensorLight OFF and
back ON again after 5 sec.
LED light does not come ON
Not properly connected Check connection (polarity)
LED light OFF although it is dark
Programme 1 or 4 selected Change programme
Troubleshooting
SensorLight without power
SensorLight will not switch ON
SensorLight will not switch OFF
Malfunction
Fuse faulty, not switched ON,
break in wiring
Short circuit
Fit new fuse; switch ON mains
switch; check wiring with volt-
age tester
Check connections
Twilight control set to night-time
mode during daytime operation
Power switch OFF
Fuse faulty
Detection zone not properly
targeted
Internal electrical fuse has been
activated
(red LED flashing rapidly)
Mains terminal not connected
properly
Reset (control dial )
Switch ON
New fuse, check connection
if necessary
Re-adjust
Switch SensorLight OFF and
back ON again after 5 sec.
Firmly press terminal together
Permanent movement in the
detection zone
Sensor unit is not properly
engaged
Check detection zone and
re-adjust if necessary
Lightly press sensor unit to clip
it into place
Basic brightness does not go out
at about midnight as desired
External light source
(e.g. other motion detector
or light) inactivating the
SensorLight
Shade SensorLight from
extraneous light, observe
SensorLight for several days
as it takes time to return to
the correct value
SensorLight will not switch OFF
completely
Basic brightness selected Programme selector switch
set to 1 or 4
Cause Remedy
Manual override function
If a mains switch is installed in the mains supply lead,
the light is capable of the following functions in addition
to the simple ON/OFF function:
Sensor operation
1) Switch light ON (when light is OFF):
Switch OFF and ON once.
Light stays ON for the period selected.
2) Switch light OFF (when light is ON):
Switch OFF and ON once.
The light goes out or switches over to sensor mode.
Manual override
1) Activate manual override:
Turn switch OFF and ON twice. The light is set to stay
on for 4 hours (red LED lights up behind lens). Then it
returns automatically to sensor mode (red LED off).
2) Deactivate manual override:
Switch 1 x OFF and ON. The light goes out or switches
over to sensor mode.
Important:
The switch should be actuated in rapid succession (in
the 0.5 –1 sec. range).
Adjusting the detection zone
The detection zone can be limited to suit require-
ments. The shrouds supplied with the light can be
used to mask out as many lens segments as you
wish. This prevents the light from being activated
unintentionally, e.g. by cars, passers-by etc. and
allows you to target danger spots. The shrouds can
be cut along the pre-grooved vertical divisions.
Then you simply clip them onto the lens.
Operation / Maintenance
The SensorLight is suitable for switching light ON
automatically. Weather conditions may affect the way
the SensorLight functions. Strong gusts of wind,
snow, rain or hail may cause the light to come ON
when it is not wanted because the sensor is unable
to distinguish sudden changes of temperature from
sources of heat. The detector lens may be cleaned
with a damp cloth if it gets dirty (do not use cleaning
agents).
Technical specifications
Declaration of conformity
This product complies with
- Low-Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
- RoHS Directive 2011/65/EC
- 16 -
Dimensions (H x W x D): 410 x 205 x 95 mm (L 675 LED)
205 x 205 x 95 mm (L 676 LED)
Material: Aluminium (base)
PMMA (diffuser)
Power supply: 230 – 240 V/50 Hz
Output: L 675 LED: 8 W LED main light
1 W LED house number illumination
155 lm
L 676 LED: 8 W LED main light
140 lm
Colour temperature: 3200 kelvin (warm white)
LED life expectancy: 50,000 hours
Detection angle: 360° with sneak-by guard
Detection reach: 8 m all round
Twilight setting: 2 – 2000 lux
Time setting: 5 sec. – 15 min.
Basic light level: 0 or 25%, soft light start
Manual override: 4 hours (selectable)
IP rating: IP 44
Protection class: II
GB
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steinel L 676 LED at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steinel L 676 LED in the language / languages: All languages as an attachment in your email.

The manual is 2,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info