1110
GB
Operation
Technical Specifications
If you want the connected
load to come on independ-
ently of a heat source in the
detection zone, briefly oper-
ate the indoor mains power
switch. The connected load
is subsequently activated
for the set time. Weather
influences may affect the
function of the SensorLight.
In case of strong gusts
of wind, snow, rain and
hail, switching errors may
occur, since the sudden
temperature deviations can-
not be distinguished from
sources of heat. The multi-
lens (detector lens) can be
cleaned with a damp cloth
if it gets dirty (do not use
cleaning agents).
Function
Once the SensorLight has
been connected and attached
to the wall mount, the system
can be switched on. Three set-
ting controls are provided on
the light's sensor lens.
a) Twilight setting
You can set the light to
come "ON" at any light level
from approx. 2 lux to 2000
lux. Control turned fully
clockwise means daytime
operation at approx. 2000
lux. Control turned fully
anticlockwise means twi-
light operation at approx. 2
lux. (Light is set to daytime
operation on leaving the
factory.) The SensorLight
control must be turned fully
clockwise when adjusting
the detection zone and
performing the function test
in daylight.
b) Switch-off delay (time
setting)
The "ON" time can be var-
ied continuously between
approx. 10 sec. and a
maximum of 15 min. Con-
trol turned fully clockwise
means shortest time of
approx. 10 sec., control
turned fully anticlockwise
means longest time, ap-
prox. 15 min. (Light is set to
shortest time on leaving the
factory.) The shortest time
setting is recommended
when adjusting the Sen-
sorLight's detection zone
and performing the func-
tion test.
Infinitely variable
brightness control
(Watt-o-matic)
The following functions
can be controlled using the
dimmer:
1) Control turned fully clock-
wise means that the Sen-
sorLight is switched
"OFF". The light on-
ly switches to maxi-
mum output when move-
ment occurs in the sensor
zone.
2) Turning the control from
the middle setting to ful-
ly anticlockwise infinite-
ly varies SensorLight
brightness from approx.
10 watts to a max. of 30
watts (light "ON"
perman
-
ently). This means: At
a permanent light "ON"
setting, for example, of
30 watts, the light will
only switch to maximum
output (60 watts) when
movement occurs in the
sensor zone.
3) Dimmer control turned
fully anticlockwise and
twilight setting control
turned fully clockwise:
In this setting, the Sen-
sorLight is permanent-
ly "ON". Using an "ON/
OFF" switch fitted in the
building's electrical wir-
ing system, the Sensor-
Light can be operated as
a normal light.
0 – 50 %
approx. 10 sec. – max. of 15 min.
Power supply: 220 – 240 V/50 – 60 Hz
Output: 60 W bulb max.
Power consumption: 0.7 W
Detection angle of sensor: 360° all-round detection
(with 120° angle of aperture)
Swivelling range of the sensor: 2 x 40° in either direction
"ON" time, adjustable: 10 sec. - 15 min.
Twilight setting, adjustable: 2 lux – 2000 lux
Sensor reach (dependent on the sensor
setting, ambient temperature and
direction of approach):
from the front: 12 m max.
from the side: 6 m max.
Type of enclosure, splashproof: IP 44
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steinel L 115 S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steinel L 115 S in the language / languages: All languages as an attachment in your email.

The manual is 3,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info