Malfunction Cause Remedy
Without power
n Fuse faulty,
not switched ON
n Short circuit
n Replace fuse, turn ON
mains switch, check lead
with voltage tester
n Check connections
Troubleshooting
Does not switch ON
n Twilight setting in
night-time mode during
daytime operation
n Bulb faulty
n Mains power switch OFF
n Fuse faulty
n Detection zone not targeted
n Adjust setting
n Replace light bulbs
n Switch ON
n Fit new fuse, check con-
nection if necessary
n Re-adjust
Does not switch OFF
n Continuous movement in
the detection zone
n Light being operated is
located in detection zone
and keeps switching ON as
a result of temperature
change
n Set to continuous operation
by indoor two-circuit single
interruption switch
n Check zone, adjust or fit
shrouds if necessary
n Change zone, or fit shrouds
n Set two-circuit single inter-
ruption switch to automatic
operation
Keeps switching ON/OFF
n Light being operated is
located in detection zone
n Animals moving in the
detection zone
n Change zone or fit shrouds,
increase distance
n Change zone or fit shrouds
Switches ON when it
should not
n Wind is moving trees and
bushes in the detection
zone
n Cars in the street are being
detected
n Sudden temperature
changes due to weather
(wind, rain, snow) or air
expelled from fans, open
windows
n Change zone or fit shrouds
n Change zone or fit shrouds
n Change detection zone,
change site of installation
- 14 -- 14 -
1. Light without neutral conductor 2. Light with neutral conductor
3. Connection using series switch for
manual and automatic operation
1) e.g. 1–4 x 100 W filament bulbs
2) Loads, lighting of 1000 W max. (see Technical specifications)
3) IS 360 D TRIO connection terminals
4) Indoor switch
5) Indoor two-circuit single interruption switch, manual operation, automatic operation
6) Indoor two-way switch, automatic operation, manual override
The motion detector is suit-
able for switching a light ON
or triggering an alarm. The unit
is not suitable for burglar
alarm systems as it is not
tamperproof in the manner
prescribed for such systems.
Weather conditions may affect
the way the motion detector
works. Strong gusts of wind,
snow, rain or hail may cause
the light to come ON when it
is not wanted because the
sensor is unable to distinguish
sudden changes of tempera-
ture from sources of heat.
The detector lens
4 may be
cleaned with a damp cloth if it
gets dirty (do not use cleaning
agents).
Connection examples
Operation/Maintenance
4. Connection using an indoor two-way
switch for manual override and automatic
operation
Setting I: Automatic operation
Setting II: Manual operation,
light permanently ON
Note: The system cannot be switched OFF,
it is only possible to select operation at setting
I or II.
GB
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steinel IS 360 D TRIO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steinel IS 360 D TRIO in the language / languages: All languages as an attachment in your email.

The manual is 2,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info