Operation/Maintenance
The infrared sensor can be
used for switching light ON
and OFF automatically. The
unit is not suitable for burglar
alarm systems as it is not
tamperproof in the manner
prescribed for such systems.
Weather conditions may
affect the way the motion
detector works. Strong gusts
of wind, snow, rain or hail
may cause the light to come
ON when it is not wanted be-
cause the sensor is unable to
distinguish sudden changes
of temperature from sources
of heat. The detector lens
may be cleaned with a damp
cloth if it gets dirty (do not
use cleaning agents).
Connection examples
1. Light without neutral conductor 2. Light with neutral conductor
3. Connection using an indoor two-way switch
for manual override and automatic operation
Setting I: Automatic operation
Setting II: Manual operation, light permanently ON
Note: The system cannot be switched OFF, it is
only possible to select operation at setting I or II.
1) e. g. 1-4 x 100 W incandescent lamps
2) load, lighting 1000 W max. (refer to Technical specifi cations)
3) IS 2180-5 connection terminals
4) Indoor switch
5) Indoor two-circuit single interruption switch, manual operation, automatic operation
6) Indoor two-way switch, automatic operation, manual override
Troubleshooting
Malfunction Cause Remedy
IS 2180-5 without power
Fuse faulty, not switched
ON
Short circuit
Mains switch OFF
Replace fuse, turn ON
mains switch, check lead
with voltage tester
Check connections
Switch ON
IS 2180-5 will not switch ON
Twilight setting in night-
time mode during daytime
operation
Bulb faulty
Mains switch OFF
Fuse faulty
Detection zone not
properly targeted
Adjust setting
Change bulb
Switch ON
Fit new fuse, check
connection if necessary
Re-adjust
IS 2180-5 will not switch OFF
Continued movement in
detection zone
Light being operated is
located in detection zone
and keeps switching ON
as a result of temperature
change
Set to continuous opera-
tion by indoor two-circuit
single interruption switch
Check detection zone and
re-adjust if necessary or fi t
shrouds
Adjust detection zone or fi t
shrouds
Set two-circuit single inter-
ruption switch to automat-
ic operation
IS 2180-5 keeps switching
ON/OFF
Lamp being operated in
located the detection zone
Animals moving in
detection zone
Heat source (e.g. extractor
hood outlet) in detection
zone
Adjust detection zone or fi t
shrouds, increase distance
Adjust detection zone or fi t
shrouds
Adjust detection zone or fi t
shrouds
IS 2180-5 switches ON when
it should not
Wind is moving trees and
bushes in the detection
zone
Cars in the street are be-
ing detected
Sudden temperature
changes due to weather
(wind, rain, snow) or air
expelled from fans, open
windows
Fit shrouds to mask out
zones
Fit shrouds to mask out
zones
Change zone, move site of
installation
GB
IS 2180-5_85x120_Zentraleuropa.indd 20-21IS 2180-5_85x120_Zentraleuropa.indd 20-21 17.12.13 14:2517.12.13 14:25
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steinel IS 2180-5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steinel IS 2180-5 in the language / languages: All languages as an attachment in your email.

The manual is 3,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info