Functional warranty
This STEINEL product has been manufactured with
utmost care, tested for proper operation and safety
and then subjected to random sample inspection.
STEINEL guarantees that it is in perfect condition and
proper working order.
The warranty period is 36 months, starting on the
date of sale to the consumer. We will remedy defects
caused by material flaws or manufacturing faults. The
guarantee will be met by repair or replacement of
defective parts at our own discretion. The warranty
shall not cover damage to wear parts, damage or
defects caused by improper treatment or mainte-
nance. Further consequential damage to other
objects shall be excluded.
Claims under the warranty shall only be accepted if
the product is sent fully assembled and well packed
complete with a brief description of the fault, a
receipt or invoice (date of purchase and dealer's
stamp) to the appropriate Service Centre.
Repair Service:
Please ask your nearest service centre
how to proceed for repairing faults not
covered by the warranty or occurring
after the warranty expires.
Declaration of conformity
This product complies with
- Low Voltage Directive 2014/35/EC
- EMC Directive 2014/30/EC
- RoHS Directive 2011/65/EC
- WEEE Directive 2012/19/EC
- 13 -- 12 -
Troubleshooting
Sensor-switched halogen floodlight
without power
Sensor-switched halogen floodlight
will not switch ON
Sensor-switched halogen floodlight
will not switch OFF
Sensor-switched halogen floodlight
comes on when it should not
Malfunction
n fuse faulty, not switched ON,
break in wiring
n short circuit
n fit new fuse; switch ON mains
switch; check wiring with volt-
age tester
n check connections
n twilight setting in night-time
mode during daytime operation
n bulb faulty
n mains power switch OFF
n fuse faulty
n detection zone not properly
targeted
n adjust setting
n change bulb
n switch ON
n new fuse, check connection
if necessary
n re-adjust
n continued movement within
the detection zone
n check zone and re-adjust if
necessary or apply shroud
n wind is moving trees and
bushes in the detection zone
n cars in the street are being
detected
n sudden temperature changes
due to weather (wind, rain,
snow) or air expelled from fans,
open windows
n sensor-switched halogen flood-
light is moving (swaying) due to
gusts of wind or heavy rain
n change detection zone
n change detection zone
n change detection zone, change
site of installation
n mount sensor-switched halogen
floodlight on a firm surface
Cause Remedy
Sensor-switched halogen floodlight
keeps switching ON and OFF
n animals moving in detection
zone
n tilt sensor higher or attach
shrouds to target the sensor;
adjust zone, or attach shrouds
Technical specifications
Sensor-switched
halogen floodlight HS 150 HS 300 HS 500
Output: 150 watts max. 300 watts max. 500 watts max.
Additional switching capacity (HS 150):
Filament bulbs, – –
800 W max.,
operating on 230 V AC
Fluorescent lamp,
400 W max.,
at cos ϕ = 0.5,
inductive load
at 230 V AC
4 x 58 W each
max., C ≤ 88 µF
operating on 230 V AC
*1)
Installation: 230 – 240 V 230 – 240 V 230 – 240 V
Sensor coverage angle: 240° with 180° 240° with 180° 240° with 180°
angle of aperture angle of aperture angle of aperture
Sensor unit swivelling range: ± 80° ± 80° ± 80°
Floodlight tilting / ± 40° horizontally ± 40° horizontally ± 40° horizontally
swivelling range: + 110° to – 40° + 110° to – 40° + 110° to – 40°
vertically vertically vertically
Time setting: 10 sec. – 15 min. 10 sec. – 15 min. 10 sec. – 15 min.
Twilight setting: 2 – 2000 lux 2 – 2000 lux 2 – 2000 lux
Reach: 12 m max. 12 m max. 20 m max.
Enclosure: IP 44 IP 44 IP 44
Weight: 1060 g 1766 g 1782 g
Projected area of the spotlight
(approx. information): 240 cm
2
387 cm
2
448 cm
2
Temperature ranging from: - 20 °C to + 50 °C - 20 °C to + 50 °C - 20 °C to + 50 °C
*1)
Fluorescent lamps, low-energy bulbs, LED lights with electronic ballast
(total capacity of all connected ballasts below the value specified).
GB