Keeping the button pressed will continue to increase or re-
duce the temperature in steps of 10 °C until the rocker but-
t
on is released or the minimum or maximum temperature is
set. The temperature setting is shown on the display for
3
seconds. On lowering or increasing the temperature, the
actual temperature is then displayed at the delivery nozzle.
T
he °C/°F symbol flashes during this period. As soon as the
selected temperature is reached, this symbol stops flashing
and is displayed all the time. Blower stage 1 delivers a tem-
p
erature of 80 °C. When the tool has been operating at high
temperatures on blower stage 2 or 3 it will take a short while
t
o cool to 80 °C after switching down to blower stage 1.
While the tool is cooling down, the LCD display (10) shows
t
he actual temperature at the nozzle outlet. After switching
off, the tool stays in the last setting that was selected. The
guard sleeve (3) detaches at a bayonet catch.
Changing the power cord (HL 2020 E only)
If the power cord is damaged, it can easily be changed
without opening the casing.
1. Important! Disconnect tool from power supply.
2. Undo screw and remove cover cap .
3. Release cable grip .
4. Undo mains terminals .
5. Pull out cord .
6. Insert new cord and secure in reverse order
(1. Firmly screw down mains terminals etc.).
a
b
c
d
e
14
Residual heat indicator
(HL 2020 E only)
The residual heat indicator serves as
a visual warning to prevent injury
from direct contact with the hot
nozzle outlet. The residual heat indi-
cator also works when the tool is
unplugged.
The indicator starts working after the
tool has been in use for 90 seconds
and keeps flashing until the tempera-
ture at the nozzle outlet has fallen
below 60 °C at room temperature.
The residual heat indicator does not
show if the tool has been in opera-
tion for less than 90 seconds. Re-
sponsibility always rests with the
user and care must be taken at all
times when handling hot air tools.
Keep these safety precautions
with the tool.
- 12 -
Technical specifications
HL 1620 S
HL 1920 E
HL 2020 E
Subject to technical modifications
Voltage
Output
Stage
Airflow rate (l/min.)
Temperature (°C)
Temperature setting
Temperature display
Residual heat indicator
Protection class
(without earth terminal)
Thermostat
Thermal cut-out
Emission sound
pressure level
Total vibration value
Weight
220-230 V, 50/60 Hz
2200 W
12 3
150 150-300 300-500
80 80-630
infinitely variable in 10 °C
steps by pushbutton
LCD indicator
Yes
II
Yes
Yes
≤ 70dB (A)
≤ 2.5 m/s
2
/
K = 0.08 m/s
2
0.880 kg
220-230 V, 50/60 Hz
2000 W
12 3
150 150-300 300-500
80 80-600
Infinitely variable in 9
increments by setting dial
No
II
Yes
≤ 70dB (A)
≤ 2.5 m/s
2
/
K = 0.08 m/s
2
0.840 kg
220-230 V, 50/60 Hz
1600 W
12
240 450
300 500
No
II
Yes
≤ 70dB (A)
≤ 2.5 m/s
2
/
K = 0.08 m/s
2
0.670 kg
Safety warnings
These hot air tools are doubly protected from overheating:
1
. A thermostat switches the heater off if too much of the
air outlet nozzle is obstructed (heat build-up). However,
t
he blower continues to run. A warning triangle on the
display tells you that the heater is switched off.
Once the air delivery nozzle is clear again, the heater au-
t
omatically switches back on again after a few moments.
The warning triangle then goes out. The thermostat may
a
lso respond after switching the hot air tool off, taking it
longer than usual to reach temperature at the air delivery
n
ozzle when it is switched on again. *
2. The thermal cut-out completely shuts down the tool if it is
overloaded.
* for HL 2020 E only
For your safety
Tool description - Operation
Please note: The distance from the object you are working
on depends on material and intended method of working.
Always try out the airflow and temperature on a test piece
first. Using the attachable accessory nozzles (see acces-
sories page on the cover) the flow of hot air can be con-
trolled with maximum precision. Take care when changing
hot nozzles! When using the hot air tool in the self-resting
position, make sure it is standing on a stable, non-slip and
clean surface.
HL 1620 S
The tool is switched on and off at the two-stage switch (7)
on the back of the grip handle. Airflow and temperature can
be adjusted to 2 settings. Stage 1 reaches 300 °C at an
airflow of 240 l/min, stage 2 reaches 500 °C at 450 l/min.
This tool is intended for home use only.
HL 1920 E
The tool is switched on and off at the two-stage switch (7)
on the back of the grip handle. In addition to three-stage
speed/airflow control (stage 1 is a cold-air stage at 80 °C),
temperature can be continuously adjusted over a range of
80 °C 600 °C in settings 2 and 3 at the thumbwheel (8).
The numbers 1 - 9 on the thumbwheel serve as a guide
only. Whereas "1" means 80 °C, the maximum temperature
of 600 °C is attained at "9". Airflow can be adjusted to the
three stages of 150 / 150-300 / 300-500 l/min. The guard
sleeve (3) detaches at a bayonet catch.
HL 2020 E
The tool is switched on and off at the two-stage switch (7)
on the back of the grip handle. In addition to three-stage
speed/airflow control at the switch (7), temperature can be
continuously adjusted over a range of 80 °C to 630 °C in
settings 2 and 3 at the rocker switch (9). The target temper-
ature can be increased in 10 °C increments by pressing the
right-hand "+" side of the rocker switch (9) or reduced by
pressing the left-hand "-" side of the rocker switch (9).
GB
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Steinel HL2020E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Steinel HL2020E in the language / languages: All languages as an attachment in your email.

The manual is 4,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info