humidification). This means that it could take several hours to achieve a
measurable humidification result. If you put the air washer into opera-
tion in a very dry environment, we recommend that you set the appliance
to continuous operation («Air Humidity») and the speed level to 3 or Turbo
(«Speed») in order to effectively increase the air humidity level. Here the size
of the room and the ventilation intervals also play a role. (Also see www.
stadlerform.com/faq).
Cleaning
Prior to any maintenance, cleaning and after each use, switch off the appli-
ance and unplug the mains cable (3) from the socket.
Attention: Never submerge the appliance in water (danger of short-circuit).
For external cleaning, rub with a damp cloth and then dry thoroughly.
For internal cleaning, remove the water tank (5) and then pull out the wa-
ter tray (2) with the evaporator discs (8) (grab underneath the tray).
Rinse the water tray (2) and the evaporator discs (8) with clean water once
per week, in order to wash out the particles of dirt removed from the air.
Clean the water tray (2), evaporator discs (8) and the water tank (5) thor-
oughly every 2 weeks with a soft brush or sponge and warm water. If there
are lime scale deposits in the water tray or water tank, use a descaling
solution diluted with water (for mixture ratio, see manufacturer’s instruc-
tions). Subsequently rinse the tray and tank with tap water thoroughly.
Descale the evaporator discs (8) approx. every 4 weeks, depending on the
water hardness level. To do so, first empty out any water remaining in the
water tray (2). Then fill the water tray with a descaling solution (mixture
ratio of solution/water according to the manufacturer’s instructions) up
to 2 cm below the edge of the tray (leave the evaporator discs in the tray).
Now push the water tray back into the appliance (the tank does not have
to be inserted). Activate the buttons with a hand motion over the display.
Press the «Mode» button three times in order to start the cleaning mode.
The «Clean Mode» symbol lights up. Here the evaporator discs rotate but
the fan does not run. Thus no air is blown into the room. After 20 min-
utes in cleaning mode, the appliance stops and the «Clean Mode» display
blinks. The cleaning process may be run several times depending on the
thickness of the limescale deposits (also see Point 7 under «Setting up/
Operation»). Once the cleaning process is finished, switch the appliance
off using the On/Off switch (4). Empty the water tray and clean it thor-
oughly with tap water.
Make sure that the air inlet and outlet are cleaned regularly to prevent
the build-up of dust. Clean the air outlet (18) with a dry brush or vacuum
cleaner. The air inlet grid (17) is fitted with an air filter which can be re-
moved and cleaned with a damp cloth. Remove the filter by pulling out the
flap at the bottom using the recessed grips.
Silver Cube™
The Silver Cube (16) prevents the growth of germs and bacteria in the hu-
midifier due to the continuous release of silver ions. The use of the Silver
Cube leads to a hygienic room climate. The lifetime of the Silver Cube is
around one year. We therefore recommend that you replace the Silver Cube
at the beginning of every humidifying season. The Silver Cube starts work-
ing as soon as it comes into contact with water, and also works when the
unit is switched off.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Stadler Form Robert at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Stadler Form Robert in the language / languages: English, German, Dutch, Danish, French, Italian, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 1,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info