744247
8
Zoom out
Zoom in
Previous page
1/53
Next page
GB 8
Make sure that the sealing elements are correctly positioned under the
dummy cover and the flue gas outlet and ensure a tight seal. After screwing
in tight, fit the optional storage elements and convected air gate to prevent
airflow in reverse order and fit the lining elements (Fig. 8).
Note: The installation steps may be different depending on each stove model.
Special notes on the Piko H20 model
The Piko H20 model has gas evacuation to the side and to the top in addition
to the option of connecting the connecting piping around a corner. If the
installation situation of the Piko H2O stove has been decided already during
the planning phase, it is possible to order the stove with preassembled
matching flue gas outlet from the factory.
If the orientation of the flue gas outlet on site has to be changed, please
proceed as follows:
Installation from the top to the back/side
The flue gas outlet can be connected to the back in three different positions:
Carefully remove the top plate (A) (Fig. 9) of the stove and place it in a
protected place. When removing the top plate, ensure that the fitted dummy
cover (B) (Fig. 10) does not fall and get damaged.
A
B
C
D
EC
E
A
BC
D
E
C
E
A
BC
D
EC
E
A
BC
D
EC
E
A
BC
D
EC
E
A
BC
D
EC
E
A
B
C
D
EC
E
A
BC
D
EC
E
Fig. 1
Fig. 5
Fig. 2
Fig. 6
Fig. 3
Fig. 7
Fig. 4
Fig. 8
2.3.1 CHANGING THE FLUE GAS CONNECTION
DIRECTION
The stove is prepared for the flue gas connection at the top when delivered.
Depending on the model, the flue gas connection position can be changed
so that it is aligned to the back, to the side or around corners. Follow these
installation steps when changing the flue gas connection position:
Changing the flue gas connection direction from to the top to the
back using the example of the Senso S
Installation from the top to the back
Remove the top plate (A) (Fig. 1) of the stove carefully and place it in a
protected place. When removing the top plate, ensure that the fitted dummy
cover (B) (Fig. 1) does not fall and gets damaged. Depending on the model,
the top plate of the stove must be removed either upwards in advance or
unlocked by parallel displacement to the front (model Stovo).
In stoves with fitted heat storage stones (for example, Cubo / Piko M (Fig.
2)) or convected air regulation (Fig. 3), these components must be removed
(„2.3.6 Installing the heat storage stones on top“ on page 18).
After removing the top plate, the flue gas connection piece (C) (Fig. 4)
bolted onto the stove body is visible. Remove these by loosening the internal
hexagonal bolts (SW 13). Now remove the dummy cover (D) (Fig. 5) on the
back of the covering panel for feed-through of the flue gas pipe. Depending
on the model, the perforation for this must be broken through or 2 fixing
screws loosened.
The only visible dummy cover (E) (Fig. 6) must be unscrewed using the
internal screws (SW13) and replaced with the previously removed flue gas
outlet (C) (Fig. 4). Fit the removed dummy cover (PE) onto the upper flue gas
outlet in order to close this (Fig. 7) (screw connection SW13).
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Passo L at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Passo L in the language / languages: English as an attachment in your email.

The manual is 3.7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Passo L

Spartherm Passo L User Manual - German - 52 pages

Spartherm Passo L User Manual - Dutch - 53 pages

Spartherm Passo L User Manual - Dutch - 44 pages

Spartherm Passo L User Manual - French - 53 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info