Attention: Do not attempt to extinguish the fire with water before the fire
brigade arrives on the scene. Temperatures in a chimney fire can reach up
to 1300°C. Extinguishing water would immediately create steam. A 10-litre
bucket of water yields 17 cubic meters of steam. The enormous pressure
created as a result could cause the chimney to disintegrate. Once the chim-
ney fire has burnt itself out, the chimney must be examined by a specialist
for cracks or leakages and, if required, repaired accordingly.
6.4 MAINTENANCE
The door seal must be checked at regular intervals! If necessary replace the
seal (in the case of wear, cracks etc.).
The firebox lining is made of natural products and must thus be checked at
regular intervals. It is made of natural products that expand and contract
with every heating process. This can cause cracks to appear. The firebox lin-
ing will remain fully functional provided it is still in position and not broken.
A crack in the chamotte stone is thus not cause for complaint.
For proper functioning, annual maintenance of the stove by a specialist
(preferably before the heating season) is essential!
For non-room air sealed stoves the following also applies:
A proper door seal is of elementary importance for stoves with non-room air
sealed operation. Check the seal for visual features (pressure, wear, dents)
at least once per heating season and change immediately if damaged.
The fireplace must never be modified! Only original spare parts that have
been approved by the manufacturer may be used! If you have any questions,
please contact your specialist dealer.
6.4.1 LUBRICATION GUIDE FOR DOOR LOCKS WITH
SMARTCLOSE
Stove and fireplace inserts with SmartClose door locking mechanisms must
be lubricated at regular intervals to assure problem-free operation (once
per heating season).
For this purpose,
the scope of delivery of each fireplace
includes a tube of special stove lubri-
cation compound. This lubricating
compound is applied to facilitate ease
of movement of heavy fire doors, and
to prevent noise caused by opening
and closing the fire doors. The lubri-
cating compound must be applied at
least once a year to the spring connection
on the SmartClose and its associated roller. With fireplaces used frequently
or very frequently, it may be
necessary to shorten this
lubrication interval. Depend-
ing on the stove or type of
fireplace insert, the door lock
springs may be located below
and/or above or to the side
of the combustion chamber
door. In order to lubricate the
lock, you may use a standard
cotton swab as an aid.
To apply the lubricant
Chapter 6
Fig. 29a
Fig. 29b
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Spartherm Ambiente at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Spartherm Ambiente in the language / languages: English as an attachment in your email.

The manual is 4.14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Spartherm Ambiente

Spartherm Ambiente Usermanual and installation guide - German - 48 pages

Spartherm Ambiente Usermanual and installation guide - Dutch - 48 pages

Spartherm Ambiente Usermanual and installation guide - French - 57 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info