812339
35
Zoom out
Zoom in
Previous page
1/44
Next page
Dehumidifier
Operating mode
The operating mode of the dehumidifier function can be set here.
Summer: In the summer operating mode, the dehumidifier turns on when the target humidity is exceeded, if the S/W day tem-
perature is exceeded and the function is approved.
Summer+Circ.: In the summer+circulation operating mode, the dehumidifier turns on when the target humidity is exceeded, if the
S/W day temperature is exceeded and the heating circuit pump is running and the function is approved.
Year round: In the year round operating mode, the dehumidifier turns on when the target humidity is exceeded if the function is
approved.
Reference humidity
Reference value for the humidity in the room.
If the value set here is exceeded, the relay will turn on the dehumidifier if this is approved for the time. The dehumidifier is turned
off if the reference value hysteresis is not met.
Hysteresis
Hysteresis of setpoint for the humidity.
Dehumidifier periods
Approval time for the dehumidifier
Here the desired periods are set in which the dehumidifier is approved. For each weekday, three times can be specified, fur-
thermore, you can copy individual day to other days. The dehumidifier is shut down outside of the set times.
Solar
This function is used to control a solar pump.
Tmin St.
Enable/start temperature at sensor X:
If this value on the specified sensor is exceeded and the other conditions are not fulfilled, the controller will turn on the affiliated
pump or the valve. If the temperature on the sensor falls 5 °C below this value, the pump or the valve will be turned off again.
Δ T Solar
Switch on/switch off temperature difference for sensor X:
If the temperature difference ΔT Solar between the reference sensors is exceeded and the other conditions are fulfilled, the con-
troller will turn on the pump/valve on the corresponding relay. If the temperature difference falls to ΔT Off, the pump/valve will be
turned off again.
Tmax
Switch off temperature at sensor X:
If this value is exceeded at the specified sensor, the controller turn off the affiliated pump or the valve. If this value on the sensor is
undershot and the other conditions are fulfilled, the controller will turn on the pump or the valve.
Temperature values which are set too high can lead to scalding or damage to the system. Scalding protection must be
provided by the customer!
Starting aid
For some solar systems, in particular for vacuum tube collectors, the measurement recording on the collector sensors may be too
slow or imprecise, because the sensor is often not on the warmest spot. With an activated starting aid, the following procedure
occurs: If the temperature on the collector sensor increases within a minute by the value defined under “increase”, the solar cir-
culation pump will be turned on for the set “purging time so that the medium to be measured is transported to the collector
sensor. If there is still no normal switching condition through this, there will be a 5 minute block time for the start wizard function.
This function should only be activated by a technician if problems occur with the measurement recording. Observe in
particular the instructions from the collector manufacturer.
The menus "Purging time" and "Increase" are only displayed when the starting aid function is set to "On".
35
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sorel XHCC S62 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sorel XHCC S62 in the language / languages: English as an attachment in your email.

The manual is 3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sorel XHCC S62

Sorel XHCC S62 User Manual - German - 62 pages

Sorel XHCC S62 User Manual - French - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info