Installation
Electrical Terminals
Low voltages
max. 12 VAC / DC
Mains voltages
100 - 240 VAC, 50 - 60 Hz
Terminal: Connection for:
S1 Storage top
S2 Storage bottom
S3 Ciculation temp. (opt.)
S4* For use see hydraulic variants page 12
S5 Primary Flow temp.
V1 0-10V/PWM signal secondary pump (loading pump)
V2 0-10V/PWM additional function eg. primary pump (opt.)
S6 Not in use
+ 12V Power supply
VFS1 Temp./Flow secondary flow
VFS2 optional further temperature/ flow or temperature/ pres-
sure monitoring) Heat output in watt (optional)
The connection of the ground wire is made at the lower gray ter-
minal block.
CAN To connect several controllers with each other using a
CAN cable. Terminate the CAN Bus on both ends using
resistors, with the assignment of the CAN bus con-
nectors being arbitrary!
Terminal: Connection for:
N Network neutral conductor N
L Network outer conductor L
R1 Additional function
R2 Additional function
R3| Relay 3 (opener)
R3 Additional function
The neutral conductor N must be connected to the N terminal
block.
The PE protective conductor must be connected to the PE
metal terminal block!
For high-efficiency pumps with 0-10V /PWM signal input, power can be supplied via the additional function parallel operation V1/V2 with
relays R1 and R2, as the relays then switch on and off together with the control signals.
7
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sorel SLC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sorel SLC in the language / languages: English as an attachment in your email.

The manual is 3.76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sorel SLC

Sorel SLC User Manual - German - 21 pages

Sorel SLC User Manual - Dutch - 36 pages

Sorel SLC User Manual - French - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info