680556
53
Zoom out
Zoom in
Previous page
1/80
Next page
53
46900V001_Rev-D_EN
11. Connections and special functions of the ceiling
control unit
3. Commissioning is performed as described in Chapter
"9. Commissioning".
If the door passes the frame photocell, the
illumination power of the operator lighting is
reduced.
If the illumination power is not reduced, the frame
photocell must be realigned and the control unit
must be reset.
During commissioning, the operator learns the
exact position of the frame photocell in order to
blank it out in normal mode shortly before reaching
the door.
4. Check the frame photocell function.
11.7 Wall station
Other functions are available with the wall station. For
example, a travel command can be executed, the lighting
can be switched on or off or the operator can be locked.
The selection of the locked areas can be changed via
SOMlink. The connection features a polarity-protected
2-wire bus.
The wall station is only supported by operators from
07/2017.
WL
24V/1A
Signal
COM
GND
+24V
O
12
WL
2
4V
/
1
A
Signal
CO
M
G
ND
+
24
V
al
1
2
O
1
2
Fig. Button connection
INFORMATION
The connection features a polarity-
protected 2-wire bus.
Installing the wall station
See the separate instructions for the "Wall station" for
installation.
1. The following conditions must be met for installation
of the wall station:
a second separate access point
a suitable position with minimum height of 1.6 m.
2. Install the wall station.
3. The wall station cable for the ceiling control unit must
be firmly secured to prevent displacement.
4. Connect the wall station to the button connection.
5. The power-saving mode must be deactivated.
Set DIP switch 3 on the ceiling control unit to ON.
1
3
2
Fig. Wall station
Functions of the buttons
Opening, stopping and closing the door
Turning the lighting on and off
Locking or unlocking the operator
Opening, closing and stopping the door
1. Press the button (1) to open and close.
The door opens or closes depending on the
starting position.
2. Press the button (1) during the opening or closing
process.
The door stops:
3. Press the button (1) again.
The door moves into the respective starting
position.
Turning the lighting on and off
The button (2) lights up green when the wall station is
ready for operation and the operator is not locked.
1. Press the button (2).
Operator lighting switched on
2. Pressing the button (2) again switches the operator
lighting back off.
Operator lighting off.
INFORMATION
If the operator lighting is not switched off
manually, it switches off automatically after
60 minutes. This value can be changed via
SOMlink and a WiFi-enabled device.
The lighting cannot be switched off when the operator is
moving.
Locking or unlocking the operator
Unauthorised access can be prevented by locking
the operator. For example in the absence of the user
53


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer S 9110 base plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer S 9110 base plus in the language / languages: English as an attachment in your email.

The manual is 8,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer S 9110 base plus

Sommer S 9110 base plus Installation Guide - German - 80 pages

Sommer S 9110 base plus Installation Guide - Dutch - 80 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info