680825
37
Zoom out
Zoom in
Previous page
1/96
Next page
37
S10564-00001_Rev-A_EN
6. Installation
6.7 Installing wall control unit
Follow in particular the basic safety instructions listed
below.
The direct connection of the wall control unit to an all-pole
line disconnecter, e.g. a main switch or a power socket,
must be secured, see Chapter "8.1 Connection to
mains voltage".
DANGER
Danger due to electric current!
Contact with live parts may result
in electric current owing through
the body. Electric shock, burns or death
will result.
All work on electrical components
may only be carried out by a trained
electrician.
Before commissioning, ensure that
the mains voltage of the power source
corresponds with the voltage listed on
the operator type plate.
Do not connect the power supply until
mounting is complete.
If a battery pack is connected,
disconnect it from the wall control unit.
Then check that the operator is
disconnected from the power supply
and secure it from switching on again.
WARNING
Danger of crushing and shearing!
The door can be actuated by a key or
pull button.
If the door moves with persons or
animals in the movement area, crushing
and shearing injuries may be caused by
the mechanism and safety edges of the
door.
The wall control unit must be installed
within sight of the door.
The wall control unit must not be
installed near moving parts.
The wall control unit must be installed at
a height of at least 1.6 m.
NOTE
Do not connect the wall control unit to
the power supply until the installation
is complete to prevent damage to the
operator.
INFORMATION
All devices to be connected externally
must have a safe isolation of the contacts
from the mains voltage supply according
to EC 60364-4-41.
Wiring for external devices must be installed
in accordance with IEC 60364-4-41.
All electrical wiring, even the control
cable, must be rmly secured to prevent
displacement.
INFORMATION
In order to connect a power socket to a all-
pole line disconnecter, e.g. a main switch,
the wall control unit must be installed as
follows:
the supplied network cable is about
0.7 m long and must not be shortened or
extended.
easily visible and accessible
Fig. 1
INFORMATION
The drilling depth must be considered
concerning the ceiling and wall thickness,
particularly with prefabricated garages.
It may be necessary to reduce the hole
depth.
Only use permissible fastening materials
appropriate for the supporting surface.
1. Choose a suitable location for the wall control unit
close to an existing power socket.
The maximum length of the control cable is 5 m and
it must not be extended.
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer S 9060 Tiga at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer S 9060 Tiga in the language / languages: English as an attachment in your email.

The manual is 28,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer S 9060 Tiga

Sommer S 9060 Tiga User Manual - German - 96 pages

Sommer S 9060 Tiga User Manual - Dutch - 96 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info