680825
16
Zoom out
Zoom in
Previous page
1/96
Next page
16
S10564-00001_Rev-A_EN
3. Description of function and product
3.3 Definitions
Programming
The operator programs the path and force required to
open and close the door.
The operator saves these values. The values are saved
even if the power supply fails.
Door OPEN
The door opens or is open.
Door CLOSE
The door closes or is closed.
Interior (IN)
This side is inside the garage.
Exterior (OUT)
This side is outside of the garage.
Light signal of the trafc light
Access authorisation for the interior and exterior is
displayed by the traffic lights.
Request side, interior or exterior
A command is given from this side.
Opposite side
This side is opposite the request side.
Command from the interior
Button or radio signal give a command to open the door
from the interior. After the lead time and, if applicable, the
clearing time, the red traffic light for the interior switches
off. This gives the authorisation for drive-through from the
interior. The opposite side gets the red phase.
Command from the exterior
Button or radio signal give a command to open the door
from the exterior. If the door is closed or is in the door
OPEN end position, the red traffic light for the exterior
switches off. This gives the authorisation for drive-
through from the exterior. The opposite side gets the red
phase.
Pre-warning time
This phase affects the time before opening or closing.
The traffic light flashes red on both sides. The warning
light and the operator lighting of the carriage also flash.
The operator movement is thereby announced. The door
area must be cleared.
Open holding time
The door remains open in this phase. The traffic light of
the request side is off. The traffic light lights up red on
the opposite side. The door can only be opened but not
closed by a command from a button or hand-held remote
control. While the door is being opened, it cannot be
stopped by a command.
Example: If a command is sent while the operator is
closing automatically, it opens completely and the open
holding time is reset.
Clearing time
This phase affects the time after the open holding time
has run out. The traffic light lights up red on both sides.
The operator lighting of the carriage also flashes. This
announces movement of the operator or traffic light
switch-over for changing the drive-through direction.
The door area must be cleared.
SOMlink
SOMlink makes it possible for qualified specialists to
change the functions and settings on the door operator.
These include force and speed values as well as
operating parameters and other convenient functions.
If you would like to make changes, contact your specialist
dealer.
Multi-function relay (MUFU)
The multi-function relay is a potential-neutral changeover
contact. The multi-function relay can be configured for
other settings using the SOMlink, a WLAN-enabled
device or a Memo tiga attached to the wall control unit at
the factory.
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer S 9060 Tiga at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer S 9060 Tiga in the language / languages: English as an attachment in your email.

The manual is 28,61 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer S 9060 Tiga

Sommer S 9060 Tiga User Manual - German - 96 pages

Sommer S 9060 Tiga User Manual - Dutch - 96 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info