15. Troubleshooting
15.4 Troubleshooting table
Problem Possible causes Test/check Remedy
The operator opens
the door when the
transmitter or control
device is actuated but
does not close it
Photo eye and safety
device have been
destroyed
Check photo eye and safety
devices
Remove obstacle
The photo eye must be aligned
If necessary, have it checked and
replaced by a qualied specialist
Automatic closing
function activated
Wait to see whether the operator
starts automatically after 30
seconds
Automatic closing function
deactivated
Have the cause corrected by a
trained electrician
Operator cannot be
operated with the
control device
No power Check power supply Check the power socket with a
different device, for example with a
lamp
End switch in carriage
defective
Unlock operator and push
carriage to the centre of the track
Lock operator
Actuate transmitter
If the operator now still does not
close and open, the end switch
is defective.
Have the end switch replaced by a
qualied specialist.
The operator was
deactivated by the
emergency release
mechanism
Check that the door can be
moved manually
Pull the emergency release to
activate the operator
Control device incorrectly
connected to the
operator
Check function of operator with
a transmitter
Check wiring, correct if necessary
Transmitter defective Operator cannot be started with
the transmitter.
Check transmitter power supply
If necessary, replace the battery of
the transmitter
If necessary, replace the transmitter
with a new one
Operator defective Operator cannot be started with
the transmitter or the connected
control device.
Have operator repaired or replaced
by a qualied specialist
Electrical supply voltage
outside the approved
range
Have the mains power supply
checked by a trained electrician
Have the cause corrected by a
trained electrician
ALARM safety input
triggered
Red trafc light for exterior and
green trafc light for interior
ash quickly
Status LED is off
Reset ALARM safety input, see
Chapter "11.9 ALARM and SAFETY
connection", section "ALARM".
SAFETY safety input,
e.g. emergency stop,
triggered
Status LED is off, the status
LED flashes.
Reset SAFETY safety input, see
Chapter "11.9 ALARM and SAFETY
connection", section "SAFETY".
When a button on the
transmitter is pressed,
the door does not
open or close
Transmitter not
programmed
Radio LED does not light when
the transmitter is operated
Program transmitter
Battery in the transmitter
is at
Replace the battery of the transmitter
Transmitter defective LED on transmitter does not
light
Replace transmitter
Radio command
cannot be
programmed
Memory full All four LEDs blink cyclically
for about 3 seconds and then
go out.
Memory full, see Chapter
"10.5 Programming the
transmitter"
MEMO Identier error Incorrect MEMO All four LEDs blink cyclically for
a short time and then go out for
a long time.
The operator lighting of the
carriage blinks 4 times short and
4 times long.
Disconnect operator from the power
supply, unplug Memo,
re-supply operator with power
88


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer S 9060 Tiga plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer S 9060 Tiga plus in the language / languages: English as an attachment in your email.

The manual is 10,99 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer S 9060 Tiga plus

Sommer S 9060 Tiga plus User Manual - German - 100 pages

Sommer S 9060 Tiga plus User Manual - Dutch - 100 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info