680779
70
Zoom out
Zoom in
Previous page
1/88
Next page
70
S10931-00001_Rev-D_EN
14. Operation
14.4 Testing obstacle detection
The operator stops and reverses slightly if it encounters
an obstacle. This prevents injury and damage to
property. The door will be partially or completely opened
depending on the setting.
The partial reversion is pre-set at the factory.
Full reversion can be set via SOMlink and a WiFi-enabled
device.
INFORMATION
Reversing: The operator stops when it
hits an obstacle. Then the operator moves
slightly in the opposite direction to release
the obstacle.
In the automatic closing function, the door
opens completely.
The following safety devices are installed to detect
obstacles:
photocell (object protection)
safety contact strips (personal protection)
obstacle detection of the operator (personal
protection)
Here, also note chapter "15. Maintenance and care."
14.5 Power-saving mode
To save energy, the operator control unit switches to
power-saving mode after the factory-specified period.
Connected accessories are deactivated and then
reactivated at the next command from a button or radio.
Connected accessories may include: photocell, safety
contact strip and external radio receiver.
Because external radio receivers are deactivated in
power-saving mode, they cannot receive commands from
the remote control and send them to the operator.
Set DIP switch 3 to "ON" to power the entire system
continuously. Power-saving mode is deactivated.
DIP switch on
wall unit
ON OFF
3
ON
1234
Continuous
power to the
complete
system
activated
Power-saving
mode activated
INFORMATION
The factory-set period before the control
unit switches to power-saving mode is
20 seconds. This value cannot be changed.
14.6 In the event of a power failure
The programmed force values and end positions of the
operator remain saved in the event of a power failure.
After the power supply has been restored, the first
movement of the operator after a pulse is always door
OPEN.
Also see the information on the emergency release
in chapter "11.8 Installing and removing the
accumulator" and "14.7 Function of the emergency
release."
14.7 Function of the emergency release
In the event of a power failure, the door can be opened
from the inside using a mechanical emergency release.
Observe in particular the following safety instructions for
this chapter.
WARNING
Danger for trapped persons!
Persons may be trapped inside the
garage. If trapped persons cannot free
themselves, severe injury or death may
result.
Test the operation of the emergency
release regularly from inside and if
necessary, also from outside.
You must have faults repaired
professionally without delay.
WARNING
Danger due to falling parts of
doors!
If the emergency release is actuated,
weak or broken springs may cause
the door to close suddenly and
unexpectedly. This may cause serious
or fatal injury.
The emergency release should be used
only with the door closed.
Use the emergency release with great
caution if the door is open.
Keep persons and animals clear of
the range of movement of the door.
70


Need help? Post your question in this forum.

Forumrules
1

Forum

sommer-s-9060-pro-plus

Reset search

  • après une coupure de courant d une semaine la porte ne ferme plus complètement. comment faire un réset sur un moteur sommer s pro + merci Submitted on 5-10-2022 at 22:16

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer S 9060 pro plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer S 9060 pro plus in the language / languages: English as an attachment in your email.

The manual is 10,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer S 9060 pro plus

Sommer S 9060 pro plus User Manual - German - 88 pages

Sommer S 9060 pro plus User Manual - Dutch - 88 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info