S10931-00001_Rev-D_EN
19. Connection diagrams and functions of the DIP
switches
* 500 mA are only available if an LED warning light (max. 3 W) or no warning light is connected
Warning light
Signal
GND
24 V AC 220–240 V AC 220–240 V AC
Mains connectionTransformer
LNN
`
L
`
max.
100 mA
ChainTrack
Fig. Connection diagram
of wall control
Button
+24 V DC
COM
24 V DC/
max. 25 W
GND
external device
24 V/max. 100 mA (500 mA*)
gn
+
rt
-
wh
gn
+12 V
br
12 V/max.100 mA
Optional
Fig. Connection diagram,
motor carriage*
Supply of external accessories
OSE
8K2
* The version can vary depending on the type.
This means the use of accessories can vary.
DIP switches
on the motor
carriage
OFF
ON
ON
1
2
3
4
Automatic
closing
function
activated
Automatic
closing
function
deactivated
ON
1
2
3
4
Partial
opening
activated/
lighting
function
deactivated
Partial
opening
deactivated/
lighting
function
activated
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
DIP switches
on the wall
control unit
OFF
ON
ON
1
23
4
Membrane keypad/
Conex additional
circuit board
Membrane keypad
T1denesdoor
OPEN
Membrane keypad
T2denesdoor
CLOSE
Membrane keypad/
Conex additional
circuit board
Membrane keypad
T1, pulse sequence
Membrane keypad
T2 lighting function/
partial opening
ON
1234
Relay (MUFU)
trips: during door
movement and
if the door is not
closed*
Lighting function
ON
1234
Continuous power
to the complete
system activated
Power-saving mode
activated
ON
1234
COM and Signal
activated as button
input (partial
opening)
COM and Signal
activated as safety
contact for photocell
* e.g.: door status display
When connecting external devices, power-saving mode must be deactivated to ensure the power supply.
86


Need help? Post your question in this forum.

Forumrules
1

Forum

sommer-s-9060-pro-plus

Reset search

  • après une coupure de courant d une semaine la porte ne ferme plus complètement. comment faire un réset sur un moteur sommer s pro + merci Submitted on 5-10-2022 at 22:16

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer S 9060 pro plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer S 9060 pro plus in the language / languages: English as an attachment in your email.

The manual is 10,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer S 9060 pro plus

Sommer S 9060 pro plus User Manual - German - 88 pages

Sommer S 9060 pro plus User Manual - Dutch - 88 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info