Connections
22
Variant 1: Fraba system + photoelectric cell
Terminal 6 Cable green from the Fraba system via photoelectric
cell only if DIP switch 2 is ON
Terminal 10 regulated 24 V DC, max. 0.1 A
Terminal 11: Earth
Terminal 20 Cable brown from the Fraba system (DC 12V)
Terminal 21 Cable white from Fraba system (Earth)
Settings: see section on “Obstruction in door travel path”
Connections for signal light
controller 1
• Permissible cable cross-section: 1 mm
2
... 2.5 mm
2
.
Connection strip for the signal lights (incl. mains supply) and potential-free
relay contact (e.g. garage lighting).
Terminal Designation/function
Mains supply
L (1) AC 220 ... 240 V
N (2) Neutral conductor
PE (3) Protective earth
Voltage tap mains power
PE (4) Protective earth
N (5) Neutral conductor
L (6) AC 220 ... 240 V
Signal light connections (max. 2 x 40 W each)
N (7) Neutral conductor GI
GI (8) Signal light green inside
N (9) Neutral conductor RI
RI (10) Signal light red inside
N (11) Neutral conductor RI
GA (12) Signal light green outside
N (13) Neutral conductor RA
RA (14) Signal light red outside
Potential-free relay contact
Light (15 + 16)
Connections for signal light
controller 2
• Permissible cable cross-section: 0.5 mm
2
... 2.5 mm
2
.
Connection strip for control cable that comes from the operator.
Terminal SIG 0 Terminal 17 on control unit
SIG 1 Terminal 19 on control unit
SIG 2 Terminal 24 on control unit
Terminal 23 on control unit
Special functions
Cycle counter
Maintenance monitoring
These functions and other functions or settings can only be made with the
TorMinal.
Example: garage lighting
• Permissible cable cross-section: 1 mm
2
... 2.5 mm
2
Stairwell light – timer “Eltako TLZ12.1-230V+8..24V UC”
Potential-free relay contact
Terminal Light (15 + 16)
Can be used for controlling a stairwell light timer/time relay. The contact is
closed for 1 second.