20
Terminal bar, 24-pole
• Permissible cable cross-section: Max 1.5 mm
2
.
Terminal 1 Antenna connection 40 MHz
2 + 3 Button 1 (inside) *
4 + 5 Button 2 (outside)
6 + 7 Safety input 1 (bridge) *
8 + 9 Safety input 2 (bridge) *
10 + 11 Regulated 24 V/DC, max. 0.1 A
12 + 13 Chain (12) + rail (13) *
14 + 15 Transformer, secondary *
16
17 SIG 0 *
18
19 SIG 1 *
20 + 21 Regulated 12 V/DC, max. 0.1 A
22
23 GND (Earth) *
24 SIG 2 *
* Factory settings
Trolley board
Terminal 1 Power supply to chain
2 Power supply to rail
3 + 4 Limit switch door OPEN
5 Motor cable
6 Motor cable
7 + 8 Limit switch door CLOSED
Connect button 1 (inside)
Use the contact only for potential-free normally closed contacts.
External voltage may damage or even destroy the control unit.
Delivery status: The push-button cable is connected to push-button 1.
Terminal 2 + 3 Connection button 1 (inside)
Connect button 2 (outside)
Use the contact only for potential-free normally closed contacts.
External voltage may damage or even destroy the control unit.
Delivery status: free
Terminal 4 + 5 Connection button 2 (outside)
Connecting photoelectric cell 1
Delivery status: Jumper
Terminal 6 + 7 tested connection for potential-free contacts,
only if DIP switch 2 is set to OFF
Terminal 10 regulated DC 24 V, max. 0,1 A
Terminal 11: Earth
Settings: see “Obstruction in door travel path”
Connect 8.2 k Ohm strip
Delivery status: Jumper
Analysis 8.2 k Ohm. Connection without special analyzer.
Terminal 6 + 7 Tested adapter for 8.2 kOhm resistor;
DIP switch 2 set to OFF
Settings: see “Obstruction in door travel path”