680646
4
Zoom out
Zoom in
Previous page
1/33
Next page
General information
3
Intended use
Attention! There is a risk of injury or property damage!
Always connect the slip-door safety mechanism to safety input 2
(terminals 8 + 9). If the slip-door safety mechanism is connected
to the trolley, then the operator will not recognise the door posi-
tion.
Caution! Risk to life and limb!
Remove all ropes and loops that are required for the manual
operation of the door.
Attention! Risk of serious damage to operator!
Do not open or close the door using the operator without first
adjusting the balance weight (springs tensioned). Otherwise, the
motor (gear system) might be seriously damaged.
The operator is designed for the exclusive purpose of opening and
closing doors. Any other use does not constitute intended use.
Manufacturer is not liable for damages that arise due to non-intended
use. The risk is borne solely by the operator. Non-intended use renders
the warranty null and void.
Doors operating automatically with an operator must comply with the
standards and directives valid at the given time: e.g. EN 12604, EN 12605.
The operator may only be used in a technically perfect condition, as
intended, in a safety-conscious and hazard-conscious manner, in
compliance with the installation and operating instructions.
Malfunctions that can impair safety must be resolved immediately.
The door must be stable and warp-proof, i.e. it should not bend or warp
during opening or closing operations.
The operator is unable to compensate for any defects in the door or for
its incorrect installation.
Only use the operator in a dry, indoor environment where there is no risk
of explosion.
Do not use the operator in rooms where a hostile environment prevails
(e.g. salty air).
Terms
Abbreviations
GI Signal light green inside
RI Signal light red inside
GO Signal light green outside
RO Signal light red outside
TorMinal
Programming device The door operator can be adjusted, or special functions
can be set, with this unit. See “Accessories”.
“Teaching”
The operator “learns” the required time and the force that it requires to
open and close the door. The operator stores these values, which remain
intact even if there is a power failure.
Door OPEN
The door opens or it is already opened.
Door CLOSE
The door closes or it is already closed.
Warning time
Time prior to opening or closing; during this time the red signal lights flash
and thus indicate that the operator is in motion:
Door OPEN:
Warning time can be adjusted with the TorMinal in a range from 0...63.75
seconds, in intervals of 0.25 seconds, memory slot (mem) 027.
Factory setting is door OPEN: 4 seconds
Door CLOSE:
The warning time can be adjusted with the TorMinal in a range from
0...63.75 seconds, in intervals of 0.25 seconds, memory slot (mem) 027.
Factory setting is door CLOSE: 5 seconds
Hold open time
Time that the door remains open. The side (inside / outside) that initiated
the command to open the door gets the green signal. The door can only be
opened by a command issued via a push-button or remote control transmit-
ter; it cannot be closed. When the door is opening, no command issued can
stop it from doing so.
If the door is closing automatically and a command is reissued, then the
door opens fully. Any command issued during the hold open time restarts
the hold open time.
The hold open time can be adjusted with the TorMinal in a range from
2...255 seconds, in 1 second increments, memory slot (mem) 031. Factory
setting: 30 seconds
Clearance time
Time in which the red signal lights are illuminated after expiration of the
hold open time; thus providing time for the persons or vehicles who had the
green light to clear the entries.
Clearance time can be adjusted with the TorMinal in a range from 0 ...63.75
seconds, in 0.25 second increments, memory slot (mem) 032.
Factory setting: 10 seconds
Inside
The side which is inside the garage or the parking area.
Outside
The side which is outside the garage or the parking area.
Command inside
Radio channel 1 or button connection 1 on terminal 2 + 3
(button line connected to the control unit)
Button or radio signal for opening the door from inside and thus drive
authorisation for inside, signal light (GI) is green.
Command outside
Radio channel 2 or button connection 2 on terminal 4 + 5
Button or radio signal for opening the door from outside and thus drive
authorization for outside, signal light (GO) is green.
Command side
The side (inside or outside) that issues a command.
Functional description
The command inside/outside, which was first transmitted to the control unit,
has priority, regardless of whether it was transmitted via radio or button
connection.
Priority for “Command Outside” is set with DIP switch 3. As
soon as “Command Outside” is received the hold open time for
inside will be aborted and switched to drive authorization for
outside after the clearance time.
Operator behaviour
at factory setting
Behaviour after power connection
Door closed and operator “taught”. All signal lights are switched off. Operator
waits for a command from inside/outside. The first travel direction is always
door OPEN; if the door is already open, then the operator recognises this and
switches the signal light to green on the side that gave the command. Then
the operator closes the door after the following individual times expire:
Warning, clearance and hold open time.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer Marathon Tiga 800 SL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer Marathon Tiga 800 SL in the language / languages: English as an attachment in your email.

The manual is 2,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer Marathon Tiga 800 SL

Sommer Marathon Tiga 800 SL User Manual - German - 33 pages

Sommer Marathon Tiga 800 SL User Manual - Dutch - 33 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info