680647
17
Zoom out
Zoom in
Previous page
1/33
Next page
Safety instructions
Keep children, disabled persons, and animals away from the door.
Keep your hands clear of a door in operation and any moving parts.
Only drive into and out of the garage when the door is fully opened.
There is a risk of persons getting trapped or cutting themselves in/on the
door system’s moving parts or the edges where it closes.
Open and close the door
Command transducers (for example button, manual transmitter, etc.)
Activate 1 x.
Door opens.
Inside: Button connection 1 (terminals 2 +3) / radio channel 1
Outside: Button connection 2 (terminals 4 + 5) / radio channel 2
Door closes automatically after expiration of the set time (warning
time, clearance time, and hold open time).
Emergency release
Caution!
The emergency release mechanism may only be used
in the event of an emergency (power failure, drive failure, etc.) to
open or close the door.
Do not use it to open and close the door in other situations, as
this could damage the door or the drive mechanism.
Risk of damage!
When operating the emergency release, it is possible that the
door may open or close on its own due to the spring breaking or
the weight balance being set incorrectly. Operator can suffer
damage or be destroyed.
The operator can be engaged or disengaged in any door position.
Pull once on the emergency release cord (N): the operator disengages
and the door can be opened manually.
Pull on the emergency release cord (N) once again: The operator
locks into position; door can only be moved with the operator.
If door is fitted with a slip door but no safety mechanism for the slip
door – then install a slip-door safety mechanism (see “Accessories”).
If the door does not have a slip door and if the garage does not have
a second entrance – install a release lock or Bowden cable to pro-
vide outside release access (see “Accessories” instructions).
N
Resetting the control unit
After a control reset, the drive must be programmed again.
Push buttons (1 + 2) until the red signal lights flash.
Red signal lights flash, force settings have been deleted; release
button (1 + 2).
Overload protection
If the operator is subjected to excessive strain when opening or closing the
door, this is recognised by the control unit which then stops the operator.
After app. 20 seconds or a control unit reset, the control unit deactivates the
overload protection mechanism.
The operator can now recommence normal operation.
Operation following a power failure
The force values remain in memory even during a power failure. The
first travel movement of the operator following a power failure is always
door OPEN.
Setting the OPEN warning time
Adjustment with TorMinal *
Memory slot (mem) Setting range Factory setting
027 0–255 16
(0 ... 63.75 seconds) (4 seconds)
Setting the CLOSE warning time
Setting with TorMinal *
Memory slot (mem) Setting range Factory setting
028 0–255 20
(0 ... 63.75 seconds) (5 seconds)
Setting the clearance time
Setting with TorMinal *
Memory slot (mem) Setting range Factory setting
032 0–255 40
(0 ... 63.75 seconds) (10 seconds)
ON
OFF
max.
Options Start Code
1
1 2
81
1 2
8
S
ta
r
t
S
a
f
e
ty
W
L
Powe
r
Au
to
T
im
e
Fo
rc
e
Start
Code
21
16
Operation and handling
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer Marathon Tiga 1100 SL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer Marathon Tiga 1100 SL in the language / languages: English as an attachment in your email.

The manual is 2,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer Marathon Tiga 1100 SL

Sommer Marathon Tiga 1100 SL User Manual - German - 33 pages

Sommer Marathon Tiga 1100 SL User Manual - Dutch - 33 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info