13
Safety instructions
After installing the operator, the person responsible for installa-
tion of the operator according to Machine Directive 98/37/EC
must issue an EC Declaration of Conformity for the door system
and affix the CE mark as well as a rating plate.
This also applies to doors installed for private purposes and in
cases where the operator has been retrofitted to a manual door.
These Instructions, as well as the operator’s Installation and
Operating Instructions should be kept by the user for reference
purposes.
The force setting is relevant to the system’s safety and must
therefore be made with due care and attention. If the force set-
ting is impermissibly high then people or animals can be injured
and objects can be damaged.
Select the force setting that is as low as possible so that
obstructions are quickly and safely recognised.
Risk of damage!
When operating the emergency release, it is possible that the
door may open or close automatically due to the spring breaking
or the weight balance being set incorrectly. Operator can suffer
damage or be destroyed.
Setting door OPEN + CLOSED end
positions
While adjusting the settings, open and close the door manually.
Do not operate it with the operator engaged.
The distance that the operator moves the door can be increased/reduced
by using the switch-triggers (1 + 4).
Check that the door opens and closes completely. If it does not, its travel
must be adjusted.
Door CLOSED end position
• Unlock the trolley if it is not unlocked. Pull once on emergency
release cord (N). You should be able to move trolley back and forth
manually.
• Shut the door manually.
• Loosen the switch trigger (V) and push the trolley forwards until it
clicks in place (end switch trips), tighten the switch trigger (V).
Door OPEN end position
• Open the door manually.
• Loosen the switch trigger (H) and push the trolley forwards until it
clicks in place (end switch trips), tighten the switch-trigger (H).
• Shut the door manually.
• Lock trolley (1):
Pull the emergency release rope (N) once.
Move the trolley (1) by hand a little bit forward until the chain wheel
engages with a loud clicking sound.
Commissioning
“Teaching” the operator
The control unit is equipped with an automatic force setting facility. When-
ever the door opens or closes, the control unit automatically reads in the
force required and memorises it when the end position is reached.
• Turn on mains power: Operator and signal light control unit.
Red signal light flashes if a force setting has not been “taught”.
The first movement of the operator after applying voltage must
always be door OPEN. If this is not the case, then swap the
cables on terminals 12 + 13.
• Press button (1), door opens until reaching door OPEN end position.
• Close door, push button (1).
Reset the control unit
• Depress buttons (1 + 2) until the red signal lights flash.
• Red signal lights flash, force settings have been deleted; release
button (1 + 2).
Perform the following sequence 2x:
The red signal lights flash until operator has executed 2 complete cycles
(cycle = 1x open + 1x close) without interruption.
• Push button (1) 1x
door opens until the switch-trigger (H, door OPEN)
• Red signal lights flash.
• Push button (1) 1x
door closes until reaching switch-trigger (V, door CLOSED)
• Red signal lights flash.
When the red signal lights no longer flash, the force values are read in
and saved.
The operator has been “taught” successfully!