Safety instructions
RISK OF INJURY!
The force setting is relevant to safety and must be carried
out by trained specialists with the utmost caution. If the force
tolerance is too high, persons or animals could be injured and
objects damaged.
Select the force tolerance to be as low as possible to ensure
that obstacles are detected quickly and safely.
DANGER OF FALLING!
Actuating the emergency release can lead to uncontrolled
door movements if springs are weakened or broken, or if the
door has not been optimally weight-balanced.
NOTE!
After installation of the drive, the person responsible for the
installation must complete an EC declaration of conformity for
the door system in accordance with the Machinery Directive
2006/42/EC, and apply the CE mark and a type plate.
This is also required for private installations, including if
the drive is retrotted to a manually-operated door. This
documentation and the Installation and Operating Instructions
are retained by the operator.
Adjust door end positions for
CLOSE + OPEN
NOTE!
Only open or close the door by hand during while adjusting;
do not use the engaged drive.
The running path of the drive can be extended or shortened (V + H)
by means of the guide idlers.
Check whether the door opens and closes completely. If this isn't the case,
then the running path and/or the limit stops must be adjusted.
V
N
1
H
1
N
Door end position CLOSED
1. Unlock the carriage. Pull once on the emergency unlocking cord (N).
It should be possible to manually push the carriage back and forth.
2. Close the door by hand.
3. Loosen the guide idler (V) and push it toward the carriage until it clicks.
Limit switch switches.
4. Tightly fasten the guide idler (V).
Door end position OPEN
1. Open the door by hand.
2. Loosen the guide idler (H) and push it toward the carriage until it clicks.
Limit switch switches.
3. Tightly fasten the guide idler (H).
4. Close the door by hand.
Lock the carriage (1).
1. Pull once on the emergency unlocking cord (N).
2. Manually push the carriage a bit until the chain wheel makes an audible
click.
The chain wheel makes a loud click sound when it snaps into place.
Programming the drive
The control system has an automatic force setting. The control system
automatically records the force required during the “OPEN” and “CLOSE”
door movements and stores it when the end positions have been reached.
ATTENTION!
Before sticking in the power mains plug, ensure that the
voltage of the power source corresponds with the voltage
listed on the drive type plate.
1. Stick in the power mains plug.
The lamp (2) blinks.
2
1
Ti
me
Rese
t
Radio
LE
D
2
LED1
Time
Reset
Radi
o
LED2
LED1
1
1
NOTE!
The rst movement of the drive after switching on the mains
power must always be door OPEN. If this isn't the case, then
reverse the cables at terminals 3 + 4.
2. Press button (1).
The door opens to the until the door OPEN end position is reached.
3. Press the button (1).
The door closes until the door CLOSED end position is reached.
4. Reset the controller. Controller reset according to drive type:
see chapter “Operation/use - controller reset”
Perform the following procedure twice:
1. Press button (1) once.
Door opens to guide idler (H, door OPEN).
The lamp (2) blinks.
2. Press button (1) once.
Door closes to guide idler (V, door CLOSED).
The lamp (2) blinks.
3. If the lamp (2) lights up, the force values have been recorded and stored.
The drive has been successfully programmed.
Check door end positions OPEN + CLOSED
The running path of the drive can be extended or shortened by means of
the guide idlers.
Check whether the door opens and closes completely. If this isn't the case,
then the running path must be adjusted.
Initial operation
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sommer Duo vision 500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sommer Duo vision 500 in the language / languages: English as an attachment in your email.

The manual is 6,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Sommer Duo vision 500

Sommer Duo vision 500 Usermanual and installation guide - German - 30 pages

Sommer Duo vision 500 Usermanual and installation guide - Dutch - 30 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info