10
a) b)
Figure 8 - Minimum distances from all surfaces: a) top view of the equipment installation; b) side view of the
equipment installation
WARNING!
Keep combustible and flammable materials at a safe distance.
6.2. Installation of ducts and Smoke exhaustion systems
• The construction of the gas exhaust pipe must be suitable for the purpose
according to the requirements of the site and in compliance with the regulations in
force.
• Important! A T-inspection with a tight-fitting lid must be inserted at the outlet of
the compact pellet exhaust pipe to allow for regular inspection or discharge of
heavy dust and condensate.
• As shown in Figure 8, the exhaust ducting should be made so that cleaning and
maintenance are ensured by inserting the inspection points.
• Under nominal operating conditions, the flue gas draft must give rise to a
depression of 12 Pa, measured 1 meter above the chimney neck.
• The compact must not share the chimney with other equipment.
• The pipes outside the place of use must be double-insulated stainless steel, with
an internal diameter of 100 mm.
• The smoke exhaust pipe, can generate condensation, in this case it is
advisable to establish adequate condensate collection systems.