9
6. Compact pellet installation
Before starting the installation, perform the following actions:
• Check immediately upon receipt that the delivered product is complete and in
good condition. Any defects must be reported before installing the appliance.
• The compact has four height-adjustable feet at its base, allowing a simple
adjustment on uneven floors.
Figure 7 - Adjustable Feet
• Connect a 100 mm diameter pipe in compacts between the flue gas outlet
and a flue for exhausting fumes to the outside of the building (e.g. chimney) -
check diagrams in Section 6.3.
• If a pipe is used for combustion air intake from outside, it must not be longer
than 60 cm horizontally or contain disturbances (e.g. bends).
• Carry out hydraulic installation (see point 20).
• Connect the 230VAC supply cable to an earthed electrical socket.
• The machine is equipped with a chrono-thermostat on the control panel. As
an option, a conventional external programmer (not included) can be used to
automatically set the device's operating periods.
6.1. Installation requirements
The minimum distances of the pellet stove from particularly flammable surfaces are
shown in Figure 8.
On top of the pellet stove, a minimum distance of 100 cm from the ceiling of the
room must be maintained, especially if the ceiling contains flammable material. The
base of the compact must not be made of combustible material, (e.g. carpeting), so
there must always be adequate protection.