PRIOR TO THE FIRST MEASUREMENT
Setting date, time, and unit
of measure
Date and time must be set prior to
using the blood pressure monitor so
that every measurement value that
is stored can be time stamped.
1. If the device is switched off, push
the key (
) to display the time.
Then push and hold the key ( )
to set the year.
2. Push the key (
) to change the
[YEAR]. Each time you push the
key, the year increases by one.
3. Once the year has been set, push
key (
) to save the information
and continue.
4. Repeat steps 2 and 3 to set
[MONTH], [DAY], [HOUR], [MINU-
TE] and [UNIT OF MEASURE]
You can switch between the unit of measure
“kPA” (kilo pascal) or “mmHg” (millimetre
mercury column), where mmHg is the most
common unit for measuring blood pressure.
5.
After setting the unit of measure,
the LCD display shows done” and
then displays all settings entered
by you before switching off.
Selecting the user
A total of two users can be program-
med. 60 datasets can be stored for
each user.
1. If the device is switched off, push
the key (
) to display the current
time and selected user.
2. Push key (
) again to select
between user 1, 2 ( ) .
3. Push key (
) to confirm and
switch the device off.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Soehnle Systo Monitor 180 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Soehnle Systo Monitor 180 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info