Admin and Installation Guide M900 Description of Settings
Setting Description
Enable automatic prex Disabled: No automatic prex added.
Enabled: The base station adds the leading digit dened in Set prex for
outgoing calls.
Enabled+fallthrough on * and #: Enables detection of * or # at the rst digit
of a dialed number. In case of detection, the base station will not add the
leading digit dened in in Set prex for outgoing calls to the dialed number.
Examples, leading digit is dened as 0:
1: number dialed on handset *1234 - > number sent to pbx *1234
2: number dialed on handset #1234 - > number sent to pbx #1234
3: number dialed on handset 1234 - > number sent to pbx 01234
Default: Disabled.
Set maximum digits of
internal numbers
This setting is used to detect internal numbers. No prex number will be
added to a dialed internal number.
Default: 0.
Set prex for outgoing calls Prex number for the enabled automatic prex feature.
Permitted values: 1 to 9999.
Default: Empty.
Conguration
Conguration server address DNS or IP address of server providing conguration le to base station.
Default: Empty. Permitted values: IP address or URL.
Filename Default: Empty.
Text messaging
Text messaging Disable/enable messaging via server, if provided by third-party service.
Enable without server: Allow handsets to send messages to other handsets
supporting messaging.
Default: Disabled.
Text messaging & alarm
server
Permitted values: IP address or URL.
Default: Empty.
Text messaging port Port number of message server.
Default: 1300.
Text messaging keepalive (m) Intervals in minutes between keepalive messages. Permitted values: Positive
integers.
Default: 30.
Text messaging response (s) Frequency in seconds of response timeouts.
Permitted values: Positive integers.
Default: 30.
Text messaging TTL Text messaging time to live in seconds.
Permitted values: Positive integers.
Default: 0.
Terminal
Keep Alive (m): If other than 0, the handset sends an (emergencyLocationMsg) containing the
RSSI measurements with the interval in minutes specied in this setting.
Permitted values: Positive integer.
Default: 0
Auto Stop Alarm: Needs to be enabled to be able to use Auto stop alarm Delay
Default: Disabled.
Auto Stop Alarm Delay (s) Handsets automatically stop alarm announcement (emergencySms) after the
number of seconds specied in this setting.
Default: 30.
56


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Snom M900 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Snom M900 in the language / languages: English as an attachment in your email.

The manual is 4.38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Snom M900

Snom M900 User Manual - English - 44 pages

Snom M900 User Manual - German - 79 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info