Feature Synchronization Enables the M200SC to synchronize with Broadworks Application Server.
Changes to features such as DND, Call Forward All, Call Forward No An-
swer, and Call Forward Busy on the server side will also update the set-
tings on the handset menu and WebUI. Similarly, changes made using the
handset or WebUI will update the settings on the server.
DTMF method Select the default DTMF transmission method. You may need to adjust this
if call quality problems are triggering unwanted DTMF tones or you have
problems sending DTMF tones in general.
Unregister after reboot Enables the phone to unregister the account(s) after rebooting-before
the account(s) register again as the phone starts up. If other phones
that share the same account(s) unregister unexpectedly in tandem
with the rebooting M200SC, disable this setting.
Call Rejection Response
Code
Select the response code for call rejection. This code applies to the
following call rejection cases:
User presses Reject for an incoming call (except when Call
Forward Busy is enabled)
DND is enabled
Phone rejects a second incoming call with Call Waiting disabled
Phone rejects an anonymous call with Anonymous Call Rejection
enabled
Phone rejects call when the maximum number of calls is reached
Dial Plan
The dial plan consists of a series of dialing rules, or strings, that determine whether what the user has dialed is
valid and when the handset should dial the number.
Note: Numbers that are dialed when forwarding a call (when the user manually fowards
a call, or when a
pre-configured number is dialed for Call Forward All, Call Forward on No Answer, or Call Forward Busy)
always bypass the dial plan.
Dialing rules must consist of the elements defined in the table below.
Element Description
x
Any dial pad key from 0 to 9, including # and *.
[0-9] Any two numbers separated by a hyphen, where the second number is greater than the first.
All numbers within the range or valid, excluding # and *.
x+ An unlimited series of digits.
,
This represents the playing of a secondary dial tone after the user enters the digit(s) speci-
fied or dials an external call prefix before the comma. For instance, “9,xxxxxxx” means the
secondary dial tone is played after the user dials 9 until any new digit is entered. “9,3xxxxxx”
means only when the digit 3 is hit would the secondary dial tone stop playing.
PX This represents a pause of a defined time; X is the pause duration in seconds. For instance,
“P3” would represent pause duration of 3 seconds. When “P” only is used, the pause time is
the same as the Inter Digit Timeout (see "General Account Settings" on page 20).
(0:9) This is a substitution rule where the first number is replaced by the second. For example,
“(4:723)xxxx” would replace “46789” with “723-6789”. If the substituted number (the first
number) is empty, the second number is added to the number dialed. For example, in “(:1)
xxxxxxxxxx”, the digit 1 is appended to any 10-digit number dialed.
|
This separator is used to indicate the start of a new pattern. Can be used to add multiple dial-
ing rules to one pattern edit box.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Snom M200 SC Base Station at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Snom M200 SC Base Station in the language / languages: English as an attachment in your email.

The manual is 4.91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info