336356
6
Zoom out
Zoom in
Previous page
1/16
Next page
Instructions for the installer
24
4. Gas connection
If the appliance is installed on an oven, you must avoid running the gas tube round the
back of the oven in order to avoid overheating.
Connection to the gas supply network can be made using a rigid copper hose or a flexible
steel hose with a continuous wall and in compliance with the guidelines established by
the applicable standard. To facilitate the connection, connector A on the back of the
appliance can be orientated laterally; loosen hexagonal nut B, twist connector A into the
desired position then retighten hexagonal nut B (it is sealed with a rubber gasket). Once
the operation is complete, check the hose fittings for leaks using a soapy solution; never
use a flame. The hob is preset for natural gas G20 (2H) at a pressure of 20 mbar. To set
it up for supply using other types of gas, see “5. ADAPTATION TO DIFFERENT TYPES
OF GAS”. The gas inlet connection is threaded ½” for external gas (ISO 228-1).
Connection with a rigid copper hose: The connection to
the gas supply network must be made in such a way that it
does not cause stresses of any type on the appliance. The
connection can be made using the adapter unit D with
double cone, always inserting gasket C (provided) in
between.
Connection with a flexible steel hose: use only
continuous wall stainless steel hoses that comply with the
applicable standards, making sure to always insert gasket
C (provided) between connector A and flexible hose E.
Installation with the flexible hose must be carried out so that the length of the piping
does not exceed 2 metres when fully extended; make sure that the hoses do not come
into contact with moving parts and that they are not crushed in any way.
4.1 Connection to liquid gas
Use a pressure regulator and make the connection on the gas cylinder following the
guidelines set out in the regulations in force. Make sure that the feed pressure
complies with the values indicated in the table in “5.2 Adjustment for liquid gas”.
4.2 Room ventilation
The room containing the appliance should have a permanent air supply in accordance
with the standards in force. The room where the appliance is installed must have
enough air flow for the regular combustion of gas and for the air exchange needed in
the room itself. The air vents, protected by grills, must be suitably dimensioned in
compliance with the current regulations and positioned so that no part of them is
obstructed.
The room must be kept adequately ventilated in order to eliminate the heat and
humidity produced by cooking: in particular, after prolonged use, you are
recommended to open a window or to increase the speed of any fans.
4.3 Extraction of the combustion products
Installation must first comply with the regulations in force and must comply with the
regulation distances and positions.
Hoods set to Recirculation mode may be used only if all other ventilation requirements
and regulations are met in full.
Combustion gases may also be discharged by means of hoods connected to a flue or
ducting providing a reliable natural draft, or a fan extraction system.
An effective extraction system requires careful design by an authorised specialist,
After installation, the installer must issue a certificate of compliance.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Smeg pva140 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Smeg pva140 in the language / languages: English as an attachment in your email.

The manual is 2,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Smeg pva140

Smeg pva140 User Manual - German - 16 pages

Smeg pva140 User Manual - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info