Sensor test procedures
237
857-164636 / Rev.A
(4) = A second start flash: This signals that the second
digit of the channel number is next.
(5) = None to nine short flashes: The number of short
flashes signifies the second digit of the configured
channel number.
3 Using a multimeter, check the DC current between the
negative charging lug (A) and the water detector (B).
- With the i nitial sea water switch and a a fully charged
battery, the current should not exceed 150 µA.
- With a redesigned sea water switch (sacrificial bolt)
and a a fully charged battery, the current should not
exceed 67 µA.
- If you measure 0 µA, check the fuse on your
multimeter.
Testing on land
1 Connect the PI Service Hydrophone to the PI Operator
Unit.
2 Place the Spread and Remote sensors on a level surface
with their “transversal eyes” pointing towards each other
at a measured distance (one to three meters). Record this
distance.
3 Place the test hydrophone approximately five meters away
from both the Spread and Remote sensors.
4 Turn on the PI, and record the distance shown on its
display.
5 Multiply the recorded physical distance by a factor of 4.5
and compare it to the distance displayed by the PI.
- The physical distance between the two sensors
multiplied by 4.5 and t he displayed distance shown on
the PI should be almost identical.
Testing in water
1 Disconnect the PI Service hydrophone, and reconnect the
vessel’s normal hull mounted hydrophone.
2 Switch off the vessel’s echo sounders, sonars and other
hydroacoustical equipment to avoid interference.
3 Lower the Spread sensor (A) over the side of the vessel
with its head (C) pointing towards the hydrophone. Lower
it to minimum three meters.
4 Switch off the PI system’s interference f ilter, and observe
the numeric display.
- If the interference symbol is not
displayed, leave the
interference filter switched off to increase the system’s
range and performance.
249


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Simrad PI32 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Simrad PI32 in the language / languages: English as an attachment in your email.

The manual is 10,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Simrad PI32

Simrad PI32 User Manual - Norwegian - 98 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info