IS12 Wind Speed/Angle
28
E04054
5 APPENDIX
5.1 Fault Finding
Symptom Possible Cause Remedy
No display on any heads • Faulty connection to power • Check power connection
in the system • Fuse has blown • Replace fuse and check
power supply current
No display on one or • IS12 data cable loose or broken • Check cable linked to
more heads in system first faulty unit. Replace if
necessary
Occasional poor • Electrical interference from other • Fit interference suppressors
performance equipment on boat (see Section 4.4) to equipment responsible
Display shows “---” • Faulty connection to transducer • Check transducer connection
These simple checks should be carried out before seeking tech-
nical assistance and may save time and expense. Before contact-
ing your servicing agent please note the unit’s serial number.
5.2 Spares & Accessories
The following spares and accessories are available from local
Simrad agents. Please quote part number when ordering -
IS12Wind:R Analogue Wind Repeater
IS12Mega:R Digital Repeater
IS12Remote:F Remote Controller
SPC2M Power Cable 2m
SDC0.3M IS12 Cable 0.3m
SDC02M IS12 Cable 2m
SDC05M IS12 Cable 5m
SDC10M IS12 Cable 10m
SDC30M IS12 Mast Cable 30m
SDJ Three Way Cable Joiner
IS12TW Spare Transducer
ISPK08 Spare Wind Vane Pack
ISPK09 Spare Anemometer Cups Pack
PIC Spare Sun Cover
ISPK03 Spare Bezel & Keypad Pack - Wind