Siemens Operating Instructions RMH760B, RMK770 CE1B3133_en
Building Technologies Do you want to display the current operating state of the heating circuit? 2015-03-31
Do you want to display the current operating state of the heating circuit?
If, during automatic heating operation, you want to know
your plant’s current operating state (the room operating
mode), go to the Info level:
1. Return to the start display by pressing the ESC
button.
2. Press the INFO button.
3. Turn the OK knob until the required page appears.
If your plant comprises several heating circuits, you can
have your plant’s operating state displayed for every
heating circuit (turn the OK knob until the desired heat-
ing circuit appears).
In the same way, you can have the DHW circuit dis-
played (if present), as well as other data.
The room operating state is displayed as follows:
Heating circuit 1
Presel:
State: Comf
Cause: Time switch
Meaning:
Preselection
This is the selected room operating mode.
In the example shown, the virtual operating mode selector is set
to
.
State
This is the current state.
In the example shown, the Comfort setpoint is maintained.
Cause
Here, the cause for the current state is given. Possible reasons:
· Operating mode contact (manual changeover)
· Operating mode selector (manual changeover)
· Special day
· Holidays
· Time switch of the time program (in the example shown)
Do you want to start DHW heating?
(Only with RMH760B)
Prerequisites
The heating plant must be commissioned by the heating
engineer.
When the preconditions are met, DHW heating is ready
to be started. Select menu option Preselection and then
select operating mode
. This is the recommended
and energy-saving operating mode.
The following choices are available:
Symbol Operating mode Impact on the DHW circuit? Guide value
Automatic The DHW temperature changes according to the DHW time program, from
normal temperature to reduced temperature, or vice versa
Normal The DHW is maintained at the normal temperature 55 °C
Reduced The DHW is maintained at the reduced temperature 40 °C
Protection No DHW heating: The plant remains protected against frost however 5 °C
Path:
Main me
nu
>
DHW
>
DHW optg m
o
de
>
Preselection
Is the DHW too hot or too cold?
(Only with RMH760B)
For the DHW temperature, you have 3 setpoint choices:
· Normal setpoint to ensure the high temperature level
required for washing, bathing and showering
· Reduced setpoint to save energy
· Frost protection setpoint at a minimum temperature level
to prevent freeze up of plant
Adjust the required setpoint on the Setpoints submenu.
When making the settings, observe that …
· extremely hot DHW can lead to scalding!
· extremely hot DHW produces scale on the storage tank
and / or the heat exchanger, the thermostat, the piping
and the valves!
For this reason, make certain that the normal DHW tem-
perature will not exceed 55 °C.
Path for plant without consumer control:
Main menu
>
DHW
>
Setpoints
Path for plant with consumer control:
Main menu
>
DHW
>
Setpoints consu
m
ers
To kill legionella viruses, the DHW can be periodically heated up. This takes place automatically and there is no need for you to
make specific settings.
All that is required is that your heating engineer has activated the function.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens RMK770 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens RMK770 in the language / languages: English as an attachment in your email.

The manual is 0,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens RMK770

Siemens RMK770 User Manual - German - 14 pages

Siemens RMK770 User Manual - Dutch - 34 pages

Siemens RMK770 User Manual - French - 14 pages

Siemens RMK770 Installation Guide - All languages - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info