41501
9
Zoom out
Zoom in
Previous page
1/16
Next page
9/16
Siemens Building Technologies Raumtemperaturregler REV23RF CE1N2265en
HVAC Products 20.08.2002
The base can be fitted to most types of commercially available recessed conduit boxes
or directly on the wall.
The support supplied with the controller enables the unit to be put on a shelf. It can be
easily fitted to the controller with no need for tools.
Notes
The room unit should be located in the main living room (on the wall or free-standing
using the support provided) while giving consideration to the following points:
The distance to the receiver should not exceed 20 m or 2 floors
The unit should be located such that the sensor is able to capture the room tem-
perature as accurately as possible, without getting affected by direct solar radiation or
other heat or refrigeration sources (in the case of wall mounting, about 1.5 m above
the floor)
The unit should be located such that it can transmit signals with as little interference
as possible. For this reason, the following points should be observed:
Do not mount the unit on metal surfaces
Not in the vicinity of electrical cables and equipment such as PCs, TV sets, mi-
crowave appliances, etc.
Not in the vicinity of large metal structures or construction elements with fine
metal meshes like special glass or special concrete
In the case of wall mounting, ensure that there is sufficient clearance for removing the
controller from its base, and for replacing it
min.
10 cm
2261Z03
The receiver and switching unit should preferably be mounted near the controlled
device
The unit should be located such that it can receive signals with as little interference
as possible. For this reason, the following points should be observed (same as with
the transmitter):
Not in control panels
Not on metal surfaces
Not in the vicinity of electrical cables and equipment such as PCs, TV sets, mi-
crowave appliances, etc.
Not in the vicinity of large metal structures or construction elements with fine
metal meshes like special glass or special concrete
The location where the unit is mounted should be dry and free from splash water
The unit can be fitted to most commercially available recessed conduit boxes or di-
rectly on the wall
First, fit the base. Then, engage the controller from the top. The base can be fitted to
most commercially available recessed conduit boxes or directly on the wall
Base
Support
Planning
Controller /
transmitter REV23RF
Wall mounting
Planning
Receiver
REV-R.02/1
Wall mounting of
controller / transmitter
REV23RF
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens REV23RF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens REV23RF in the language / languages: English as an attachment in your email.

The manual is 0,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens REV23RF

Siemens REV23RF User Manual - Dutch - 15 pages

Siemens REV23RF User Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info