Description of new and updated functions
Information on operating Gigaset VoIP telephones with Network Address Translation (NAT) routers
Gigaset IP Phones / IM-BELG EN / A31008-xxxx-xxxx-x-xxxx / description.fm / 3/23/09
Version 4, 29.10.2007
Information on operating Gigaset VoIP telephones with
Network Address Translation (NAT) routers
This section amends the section "Questions and answers" in the chapter "Customer care" in the user
guide for your phone.
In general no special telephone or router configuration is required when operating a
Gigaset VoIP phone with a NAT router. The configuration settings described in this section
are only necessary if you encounter one of the following problems.
Typical problems caused by NAT
u No incoming calls are possible via VoIP. Calls to your VoIP phone number are not put
through.
u Outgoing calls via VoIP are not connected.
u A connection is established with the other party, but you cannot hear them and/or they
cannot hear you.
Possible solution
1. Change the port numbers of the communication ports (SIP and RTP ports) on your tele-
phone (
£ "1. Changing the port numbers for SIP and RTP on your VoIP phone").
2. In some cases, you must also define port forwarding for the telephone's communication
ports on the router (
£ "2. Setting port forwarding on the router").
1. Changing the port numbers for SIP and RTP on your VoIP phone
On your VoIP telephone, define different (local) port numbers for the SIP and RTP ports
(between 1024 and 49152).
u These numbers must not be used by any other application or host in the LAN and
u be considerably higher or lower than the SIP and RTP port numbers that you usually use
(and are preset on the phone).
This procedure is particularly useful if additional VoIP phones are connected to the router.
To change the SIP and RTP port numbers on your VoIP phone, proceed as follows:
¤ Connect your PC's browser to the Web configurator of the telephone and log in
(
£ user guide for your phone).
¤ Open the Web page Settings ¢ Telephony ¢ Advanced Settings and change the settings
for the SIP and RTP ports (
£ Page 23).
To help you remember the new port numbers (e.g. for router configuration), you can
choose numbers that are very similar to the standard settings, e.g.
¤ Save the changes on your telephone.
¤ Wait for the active VoIP connections to be re-registered. To do so, switch to the Web
page Settings
¢ Telephony ¢ Connections to see the Status of your VoIP connections.
¤ Check to see whether the problem persists. If it does, perform step 2.
SIP port 49060 instead of 5060
RTP port 49004 to 49010 instead of 5004 to 5010
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Siemens Gigaset S685 IP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Siemens Gigaset S685 IP in the language / languages: English as an attachment in your email.

The manual is 0,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Siemens Gigaset S685 IP

Siemens Gigaset S685 IP User Manual - English - 280 pages

Siemens Gigaset S685 IP User Manual - German - 202 pages

Siemens Gigaset S685 IP Additional guide - German - 43 pages

Siemens Gigaset S685 IP User Manual - German - 2 pages

Siemens Gigaset S685 IP Additional guide - Dutch - 42 pages

Siemens Gigaset S685 IP User Manual - Dutch - 287 pages

Siemens Gigaset S685 IP User Manual - Dutch - 80 pages

Siemens Gigaset S685 IP Additional guide - French - 42 pages

Siemens Gigaset S685 IP User Manual - French - 288 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info