787869
13
Zoom out
Zoom in
Previous page
1/96
Next page
EN
joint A
groove
3. Lead the heat discharge pipe outdoors.
Note on installing heat discharge pipe
In order to improve cooling eciency,the heat discharge pipe should be as
short as possible and at without curve to ensure smooth heat discharge.
The discharge pipe is suggested to be installed according to below gure .
Discharge pipe can be installed based on user's requirement, while
installation form as shown below should be avoided as it may lead to
non-uniform exhaust.
If the length of the heat discharge pipe is less than 1 meter. It is
recommended to use it with shortest length.
When installing, heat discharge pipe should be as at as possible. Do not
lengthen the pipe or connect it with an other heat discharge pipe.
Operation Test
Connect power and then press ON/OFF button on remote control to
start the unit.
Press mode button to select auto, cooling, dry, fan or heating function,
and then check if the unit operates normally.
If ambient temperature is below 16°C , the unit can't operate in cooling
mode.
Wiring Diagram
The electric schematic diagram are subject to change without notice.
Please refer to the one on the unit.
UL-C10EA-W
UL-C12EA-W
UL-C10UA-W
R(M)
BOARD
DISPLAY
REC
RECEIVER
BOARD
SWITCH
WATER LEVEL
RT2RT1
WATER MOTOR POWER
L
BN(BK)
N
YEGN(GN)
BU(WH)
BU
N1
S
COMP
C
YE
C1
K201
AC-L
COMP
N2
WATER1
DISP2
RD
RD
BU
RD
DISP2
DISP1
AP2
M3
PE
PE
YEGN
DISP1
PE PE
M2
OFAN
YEGN
MOTOR
DOWN FAN
C3 C2
RD
UP FAN
MOTOR
BN
M1 YEGN
FAN
AP3
AP1
MAIN BOARD COMP.
CAP.
CAP.
RD BN
CAP.
HIGH-WP
RD RD
SA
SWING
M4
STEPPING
MOTOR
SENSOR
TUBE TEMP.
T-SENSOR
ROOM TEMP.
SENSOR
UL-CY12EA-W
R(M)
OUTTUBE
RT3
BOARD
DISPLAY
REC
RECEIVER
BOARD
SWITCH
WATER LEVEL
RT2RT1
OUTTUBE TEMP.
SENSOR
WATER MOTOR POWER
L
BN(BK)
N
YEGN(GN)
BU(WH)
BU
N1
S
COMP
C
YE
C1
K201
AC-L
COMP
N2
WATER
DISP2
RD
RD
BU
RD
DISP2
DISP1
AP2
M3
PE
PE
YEGN
DISP1
PE PE
M2
OFAN
YEGN
MOTOR
DOWN FAN
C3 C2
RD
UP FAN
MOTOR
BN
M1 YEGN
FAN
AP3
AP1
MAIN BOARD COMP.
CAP.
CAP.
RD BN
CAP.
N2
4YV
4WAY
4-WAY
VALVE
HIGH-WP
RD RD
SA
SWING
M4
STEPPING
MOTOR
SENSOR
TUBE TEMP.
T-SENSOR
ROOM TEMP.
SENSOR
Specialist's Manual
Aptitude requirement for maintenance personnel
(repairs should be done only by specialists).
1. Any person who is involved with working on or breaking into a
refrigerant circuit should hold a current valid certicate from an
industry-accredited assessment authority, which authorises their
competence to handle refrigerants safely in accordance with an
industry recognised assessment specication.
2. Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of
other skilled personnel shall be carried out under the supervision of
the person competent in the use of ammable refrigerants.
Safety preparation work
The maximum refrigerant charge amount is shown on the following table.
(Note: Please refer to the nameplate for the charging quantity of R290).
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sharp UL-C10EA-W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sharp UL-C10EA-W in the language / languages: English, German, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 14.2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info