Operation Test
Connect power and then press ON/OFF button on remote control to
start the unit.
Press mode button to select auto, cooling, dry or fan function, and then
check if the unit operates normally.
If ambient temperature is below 16°C, the unit can't operate in cooling
mode.
Wiring Diagram
The electric schematic diagram are subject to change without notice.
Please refer to the one on the unit.
UL-C09EA-W
YEGN
PE
PE
ELECTRIC
BOX
CONDENSER
R(M)
REC
DISPLAY
BOARD
RECEIVER
BOARD
RT2RT1
SWITCH
WATER LEVEL
POWER
L
N
BU
N3
S
COMP
C
YE
C1
K1
L
COMP
AP1
N1 WATER1
DISP2
RD
FAN RD
BU RD
DISP2
DISP1
AP2
M1
BN
MOTOR
RD C2
PE
AP3
PE
YEGN
DISP1
COMP.
MAIN BOARD
BU(WH)
YEGN(GN)
BN(BK)
WATER MOTOR
M2
PE
YEGN
CAP.
CAP.
FAN
SENSOR
T-SENSOR
ROOM TEMP.
SENSOR TUBE TEMP.
HIGH-WP
RD RD
SA
Specialist's Manual
Aptitude requirement for maintenance personnel
(repairs should be done only by specialists).
1. Any person who is involved with working on or breaking into a
refrigerant circuit should hold a current valid certicate from an
industry-accredited assessment authority, which authorises their
competence to handle refrigerants safely in accordance with an
industry recognised assessment specication.
2. Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of
other skilled personnel shall be carried out under the supervision of
the person competent in the use of ammable refrigerants.
Safety preparation work
The maximum refrigerant charge amount is shown on the following table.
(Note: Please refer to the nameplate for the charging quantity of R290).
Room area (m) 4 11 15
Maximum charge (kg) <0.152 0.225 0.304
Prior to beginning work on systems containing ammable refrigerants,
safety checks are necessary to ensure that the risk of ignition is minimised.
For repair to the refrigerating system, the following precautions shall be
complied with prior to conducting work on the system.
Work procedure
Work shall be undertaken under a controlled procedure so as to minimise
the risk of a ammable gas or vapour being present while the work is being
performed.
General work area
All maintenance sta and others working in the local area shall be
instructed on the nature of work being carried out. Work in conned
spaces shall be avoided. The area around the workspace shall be sectioned
o. Ensure that the conditions within the area have been made safe by
control of ammable material
Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to
and during work, to ensure the technician is aware of potentially toxic or
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sharp UL-C09EA-W at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sharp UL-C09EA-W in the language / languages: English, German, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 30.7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info