Operating instructions for the user 9
1 Introduction
What is sauna and climate operation?
With this sauna and climate control you can switch from
one kind of bath to another.
Figure 1 shows the usual temperature and relative
humidity values for sauna and climate operation.
Figure 1
10 20 30 40 50 60 70 80 90 100
10
20
70
60
50
40
30
80
90
100
Relative humidity in percent
Temperature in Celsius degrees
0
SAUNA
CLIMATE
During sauna operation you will have dry heat at your
disposal. The heat value is high, typically up to 100°
C, the humidity is low.
During climate operation the temperature in the sauna
cabin will be lower, but the relative humidity will be
significantly higher.
NOTE - Changing modes:
To avoid unintentional switching from sauna to cli-
mate operation, changing modes during operation is
not possible. First press START/STOP 7 then
change the mode of operation and start again.
1 Introduction - Continued
Possible relative humidity of a temperature in
climate operation:
During climate operation the temperature values and
the relative humidity values are interdependent. As a
principle: High temperature, low humidity; and high
humidity, low temperature.
Figure 2 shows the possible relative humidity of a
certain temperature. For example, at 65° C a relative
humidity of a maximum of 30% is possible.
Figure 2
10 20 30 40 50 60 70 80 90 100
65
10
20
70
60
50
40
30
80
90
100
Relative humidity in percent
Temperature in Celsius degrees
0
Possible relative
humidity of given
temperature
When programming the temperature and the relative
humidity in climate operation:
If an invalid entry for the interdependent values of
temperature and rel. humidity is made, a signal will
sound and the value entered first will be changed to
a valid setting.
Example: If you set the temperature at 65° C, you can
set the relative humidity to a maximum of 30%. If you
enter a value higher than 30% and press OK 9, a
signal will sound and the temperature will be reduced
to the permissible temperature value.
The reduced value will be displayed and can then be
changed or confirmed.
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sentiotec CK 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sentiotec CK 3 in the language / languages: English, German as an attachment in your email.

The manual is 0,33 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info