- 11 - 09/2020 Copyright © 2020, F ast ČR, a.s.
Automatic defr osting
In the event that frost forms around the vaporizer c oil, the appliance will automatically
switch to the automatic defrost mode until it eliminat es the frost. In this mode, the
compressor will turn on in regular intervals and the fan will run continuously . Indicator
light B13 will be lit on the control panel A2 .
DRAINING CONDENSA TE
For the purpose of draining condensate y ou can use the condensate tank A3 , drain hose
outlet A6 or the pump drain hose outlet A8 .
Draining condensate int o the tank
Prior to turning on the appliance, check that outlets A6 and A8 are fitt ed with plugs.
During operation, condensate will accumulate in the tank A3 . As soon as it fills up , the
indicator light B12 will be lit and the appliance will turn off automatically . Error message
"P2 " will appear on the display B9 .
Carefully slide out the condensate tank A3 , careful not t o spill any water . The bottom
of the condensate tank A3 is not level, theref ore do not stand it on the floor when the
condensate tank A3 is full. Empty out the condensate tank A3 and insert it back into
the appliance. Check that the condensate tank A3 is corr ectly installed. The appliance
will automatically resume operation.
When removing the condensate tank A3 , be careful so as not t o drop it and damage the
internal parts of the appliance. Do not use excessiv e force when installing the condensate
tank A3 into the appliance. Using brute f orce may damage the appliance.
If the hose falls out while removing the condensate tank A3 , it is necessary to put it back
in its place before inserting the condensate tank A3 into the appliance .
If there is any water in the installation area of the c ondensate tank A3 , wipe it using
adry wiping cloth.
If you remove the condensate tank A3 while the applianc e is running, the compressor
and the fan will stop, abeep will be made and the error message "Eb " will appear on
the display A9 .
If you remove the condensate tank A3 while the applianc e is turned off, abeep will be
made and the error message "Eb " will appear on the display A9 .
Continuous condensa te draining via the drain hose
For continuous draining of c ondensate, screw off the plastic plug anticlockwise from
the drain hose outlet A6 . Carefully store the plug f or future use.
Note:
If there is water in the outlet when the plug is remov ed, wipe it using a dry
wiping cloth.
Properly screw in the threaded end of the dr ain hose A6 to the outlet. T o ensure that
condensate does not leak, check that the hose end is properly screwed in.
Locate the free end of t he hose so that the condensate can flow out freely . The container
or place where the condensate is drained must be low er than the outlet A6 . Do not
bend or twist the hose.
Set the required humidity and fan speed to start the appliance.
Note:
When not using the drain hose for continuous draining of condensa te, screw
off the hose, wipe away nay wa ter and close the outlet A6 using the plug.
Draining condensate using apump
Screw the plug out of the pump drain hose outlet A8 . Check that aplug is installed in
outlet A6 . Insert the pump drain hose at least 15 mm deep into outlet A8 . T o ensure that
condensate does not leak, check that the hose end is properly screwed in.
Locate the free end of t he hose so that the condensate can flow out freely . The container
or place where the condensate is drained must be low er than the outlet A8 . Do not
bend or twist the hose.
Press button PUMP B1 to activate the draining of c ondensate using apump.
Condensate will be fed into the c ondensate tank A3 , and once the condensate tank A3
is full the pump will automatically be started, which will drain the condensate from the
condensate tank A3 out of the appliance.
Note:
Y ou may hear anoise while the pump starts up. This is normal . The pump will
run for approximat ely 3 – 5minutes.
If the indicator light above button PUMP B1 starts flashing, then amalfunc tion with
the pumping out of the condensate has occurred. Turn off the appliance using button
B8 and disconnect the power cord from the pow er socket. Check the following points:
- Check that the pump filter is clean.
- Remove the condensate tank A3 out of the appliance , remove the pump and clean
out the filter .
- Check that the pump hose is not twisted or bent.
- Empt y out the condensate tank A3 .
- Screw out and reattach the pump drain hose. Remove and r einstall the condensate
tank A3 . T urn on the appliance and if the problem persists, please contact an
authorised service centre.
Note:
Do not run the appliance in this mode at a temperature of 0 °C or less.
Otherwise frost may form inside the appliance, condensate my freez e in the
drain hose and the appliance may subsequently be damaged.
In this condensate draining mode, it is important to pour condensate out of the
condensate tank A3 at least once per week.
When not using the pump drain hose to drain the condensate , carefully remove the
hose from the outlet A8 and close the outlet A8 using the plug. Be careful not to spill
water from the drain hose on to the floor .
CLEANING AND MAINTENANCE
Disconnect the power plug from the power socket bef ore cleaning.
Note:
For cleaning, do not use cleaning pr oducts with an abrasive effect, solvents,
etc. that could damage the appliance.
Warning:
T o prevent the risk of injury by electrical shock, do not submerge
the appliance, power cor d or power plug in water or another liquid.
Cleaning the condensate tank
Empty out the condensate tank A3 whenever you finish using the appliance and wipe
it using awiping cloth.
T o prevent undesirable bacteria, micro-organism or moulds from multiplying inside
the tank A3 , clean it out at least once per month using acloth dampened in lukewarm
water with the addition of neutral detergent. Then rinse it out thoroughly using clean
water , wipe it dry and inser t it back into the appliance.
Do not wash the tank A3 in adishwasher .
Cleaning the air filter
After approximately 250 hours of operation, the indicator light above button FIL TER B3
will be lit, signalling that the filter requires cleaning .
Release the grille A11 and then carefully remove the filters A10 . Wash the filter A10
in warm water with a small amount of kitchen detergent. Then thoroughly rinse it
under running water and allow it to dry naturally . Install the filter A10 back in its place.
However , first make sure that the filter A10 is completely dry. Then reattach the grille A11 .
Warning:
Do not use the appliance without the filter A10 being properly
installed. Never wash the filter A10 in adishw asher.
Cleaning the outer cov er and air outlet grilles
T o clean the air outlet grille A11 and the outer cover , use awiping cloth lightly dampened
in lukewarm water with a small addition of neutral detergent. Make sure that wat er
does not enter into the vents. In the even t that the grille A11 is only dusty, avacuum
cleaner may be used to clean it.
Storage
When not using the appliance for an extended period of time, disconnect the power
plug from the power socket and clean it accor ding to the instructions provided above.
Clean the condensate tank A3 only 24hours after turning the appliance off since even
during this time asmall amount of condensate may accumulate .
Wind the power cor d around the holder.
Store the appliance in a dry, clean and well-ventilated location not exposed t o extreme
temperatures and out of children'sr each.
TROUBLESHOOTING
Problem Solution
The dehumidifier
cannot be turned on.
Check that the power cord plug is corr ectly connected to
apower socket.
Check that fuses are in order .
The dehumidifier reached the set humidity level or the
condensate tank A3 is full.
The condensate tank A3 is not correctly installed.
The dehumidifier is not
removing humidity
from the room.
The dehumidifier has only been running for ashort time,
please wait afew more moments.
Make sure that there are no curtains, roller blinds or
furniture in front of the dehumidifier .
The humidity setting is insufficient.
Check that the doors, windows and other openings in the
room are properly closed.
The temperature in the room is t oo low (below 5°C).
There is an appliance located in the room tha t may be
creating humidity.
The dehumidifier is too
noisy while running.
The air filter is clogged.
The dehumidifier is tilted.
The floor is not level.
Frost is f orming inside
the appliance.
The dehumidifier is equipped with an automatic defrost
function, which is activated when frost starts to form.
There is water on the
floor .
Check the hose for damage and that it is correctly
attached.
Disconnect the hose and use the condensate tank A3 to
drain the condensate. Close outlets A6 andA8 using plugs.
Indicator light above
PUMP B1 is flashing.
Clean out the pump filter .
Check that the drain hose is not crimped of clogged.
Empty out the condensate tank A3 .