2. Automatic turn-off function
While the portable air conditioner is running, press the button C9. Press the
button C9 repeatedly to set the time after which the portable air conditioner will
turn off automatically. You can set the time of the automatic turn-off function in the
range from 1 up to 24 hours.
After afew seconds, the set time will be saved in the air conditioner memory and the
automatic turn-off indicator will be lit on the display C5. Once the set time elapses,
the portable air conditioner will turn off automatically.
If you press button C9 or button C14 after the automatic turn-off function is
set, the setting will be automatically cancelled.
3. Change of the temperature unit
Press and hold +/- buttons simultaneously to change the temperature unit from°C.
to °F and vice versa.
4. Wi-Fi function (valid only for Wi-Fi models)
You can also control the portable air conditioner directly from your smart phone
thanks to the “TuyaSmart” application.
Install the TuyaSmart” application on to your smart phone. The application is
available for operating systems iOS (App Store) and Android (Google Play). Further
follow the instructions in the application.
google
App Store
In order to control the portable air conditioner using the installed application, it is
necessary the Wi-Fi is turned on.
While the portable air conditioner is off (it is in stand-by mode), press the button
C10 six times within four seconds to reset the Wi-Fi signal. An audible alert sounds.
If the function is on, the indicator C2 will be lit.
B. REMOTE CONTROL
Inserting and replacing batteries
Slide out the battery compartment cover, which is located on the rear side of the
remote control. Place two AAA/LR03 (2× 1.5 V) alkaline batteries into the battery
compartment and close the cover.
When inserting the batteries ensure the correct polarity as shown in the battery
compartment.
When replacing the batteries, always use batteries of the same type, never combine
old and new batteries or batteries of various types.
Note:
Removing the batteries from the remote control will delete all the
settings. After new batteries are inserted the default remote control
settings as programmed by the manufacturer will be renewed.
If you do not use the remote control for longer than 2 months, remove
the batteries.
Caution:
Dispose the used batteries according to the local regulations.
Never dispose the batteries together with the household waste.
Do not use old and new batteries at the same time. Do not use
alkaline, standard, and rechargeable batteries at the same time.
Do not throw batteries into fire. They may explode or leak.
Using the remote control
For the remote control to work correctly, ensure that the maximum distance of the
remote control from the portable air conditioner is not greater than 7 m and that
there is no obstacle between the remote control and the portable air conditioner
that could prevent the transmission of the signal.
Point the remote control directly at the portable air conditioner. The transmission of
the signal is confirmed by ashort sound signal.
Do not expose the remote control to direct sunlight or high temperatures.
Otherwise, the signal may not be transmitted.
Turning the portable air conditioner on and off
Press the button D1 once to turn the portable air conditioner on. Press it again to
switch the portable air conditioner to the stand-by mode.
OPERATING MODES
1. Cooling mode
Repeatedly press the button D2 until the cooling indicator C6 is lit. Use the +/-
buttons to set the desired temperature. You can set the temperature in the range
from 18 to 32°C.
Use the button D7 to set the fan speed in the following order: High (high speed)
– Low (low speed). Each time the button is pressed, the respective indicator will be
lit on the control panel A1.
2. Fan mode
Repeatedly press the button D2 until the fan indicator C8 is lit. Use the
button D7 to set the fan speed in the following order: High (high speed) – Low (low
speed). Each time the button in pressed, the respective indicator will be lit on the
control panel A1 and at the same time, the respective graphic symbol ( symbol
for high speed; symbol for low speed) will be lit on the display C5. In this mode,
it is not possible to set the temperature, nor it is necessary to connect the flexible
hose B4 to the portable air conditioner.
Note:
In the fan mode, it is not possible to set the temperature.
3. Dehumidification mode
Ensure the flexible hose B4 is connected to the air conditioner. Repeatedly press the
button D2 until the dehumidification indicator C7 is lit. The display C5 shows
. In this mode, it is not possible to set the temperature or fan speed. The fan
speed is automatically set.
FUNCTIONS OF THE PORTABLE AIR CONDITIONER
1. SLEEP FUNCTION
The sleep function is used to reduce overnight power consumption when aconstant
temperature is not necessary. The function also ensure comfort while sleeping as the
air conditioner operation is turned down and the display illumination is dimmed.
Select the operation mode – see the previous part of the manual.
Press the button D5. The portable air conditioner will operate in the previously
selected mode.
When you choose the sleep function, the display illumination C5 will be dimmed
and the fan will be automatically set to low speed.
When the cooling mode was selected, the temperature will increase by 1°C. per
hour in a2-hour period. This new temperature will be maintained for six hours and
then the portable air conditioner will be turned off.
The sleep function can be cancelled at any time by pressing the button D5,
button D2 or button D7.
2. AUTOMATIC TURNON AND TURNOFF FUNCTIONS
Automatic turn-on
Automatic turn-on function enables to set the time after which the portable air
conditioner will turn on automatically.
Turn the portable air conditioner on by pressing the button D1. Use the
button D2 to select the operation mode in which you wish to turn the portable air
conditioner on. Use the +/- buttons to set the desired temperature and use the
button D7 to set the fan speed as required. Press the button D1 to turn off the
portable air conditioner.
Press shortly once the button D4. Press the button D4 repeatedly to set the
time after which the portable air conditioner will turn on automatically. You can set
the time of the automatic turn-on function in the range from 1 up to 24 hours.
After afew seconds, the set time will be saved in the air conditioner memory and the
automatic turn-on indicator will be lit on the display C5. Once the set time elapses,
the portable air conditioner will turn on automatically.
If you press button D4 or button D1 after the automatic turn-on function is
set, the setting will be automatically cancelled.
Automatic turn-off
Automatic turn-off function enables to set the time after which the portable air
conditioner will turn off automatically.
While the portable air conditioner is running, press once the button D4. Press the
button D4 repeatedly to set the time after which the portable air conditioner will
turn off automatically. You can set the time of the automatic turn-on function in the
range from 1 up to 24 hours.
If you press button D4 or button D1 after the automatic turn-on function is
set, the setting will be automatically cancelled.
3. CHANGE OF THE TEMPERATURE UNIT
When the portable air conditioner is in stand-by mode, press the button D8 to
change the temperature unit from°C. to °F and vice versa.
FLAP ANGLE ADJUSTMENT
The air outlet A2 is provided by movable flaps. If you need to adjust the air flow, you
can adjust it by hand to the desired angle by moving up and down.
Be careful while handling the flaps not to damage them. We recommend adjusting
the flap angle before turning the portable air conditioner on.
TIPS FOR CORRECT USE
To ensure the correct operation of the portable air conditioner, follow these
recommendations:
- Close all the windows and doors in the room where the portable air conditioner
is used. When installed the portable air conditioner semi-permanently, you can
leave the door slightly open (approx. 1cm) to guarantee correct ventilation.
- Protect the room from the direct sunshine. Close curtains or roller blinds to
ensure economy operation of the air conditioner.
- Do not block the air inlet or air outlet.
- Ensure there is no source of heat on in the room.
- Never use the portable air conditioner in very damp rooms, such as laundries.
- Never use the portable air conditioner outside.
- Ensure the portable air conditioner is located on alevel surface. Install special
travel wheel brakes if needed.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Sencor SAC MT7007C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Sencor SAC MT7007C in the language / languages: English as an attachment in your email.

The manual is 3,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info