757456
12
Zoom out
Zoom in
Previous page
1/15
Next page
22
English
23
English
USE OF TERMS IN THIS MANUAL
DEFINITION OF THE TERMS AND BASIC DESIGN OF THE WATCH
The watch measures the depth of water
from 1.5 m (5 ft) up to 99.9 m (328 ft) in 0.1 m
(1 ft) increments. The measurement is made
on the basis of seawater having a specific
gravity of 1.03.
Ex.) If the displayed depth of the water is 19.4
m (64 ft) in fresh water (specific gravity
1.00), the actual depth is:
19.4 m (64 ft) x 1.03/1.00 = 20.0 m (66 ft)
No-decompression limits and residual
nitrogen the watch provides are calculated
on the basis of water pressure only, and can
be used while diving in fresh water without
any conversion.
The watch measures and indicates dive time
in one minute increments up to 599 minutes.
It starts measuring the time when the diver
descends more than 1.5 m (5 ft), and stops
when the diver ascends to a depth of less
than 1.5 m (5 ft).
Terms Definition and basic design of the watch
Depth
Dive time
(DIVE. T)
Definition and basic design of the watchTerms
The watch measures the water temperature
in 0.1° C (1° F) increments from -5.0° C up to
+40.0° C (23° F up to 104° F). The water
temperature recorded in the dive log function
is a measurement taken at the maximum
depth.
Water
temperature
Surface
interval
time
(SURF. T)
The watch measures the time spent on the
surface in one minute increments up to 48
hours, starting from the time when the diver
ascends to a depth of less than 1.5 m (5 ft).
If the diver descends to a depth of greater
than 1.5 m (5 ft) when the surface interval
time is less than 10 minutes, the previous
and the new dives are considered
inseparable, and the dive times of both dives
and the surface interval time are added
together.
When more than 30 dives are made:
If a new dive is made when log data of 30 dives are stored
in memory, the log data for the oldest dive is erased from
memory and the data for the new one is recorded in
memory.
In that case, log No. for the existing data will be reduced by
one.
Dive that is not recorded in the dive log function
Even if the dive function is started by measuring a depth greater than
1.5 m (5 ft), a dive that lasts less than 3 minutes will not be recorded.
How to erase the log data in memory
The entire log data stored in memory can be erased as
required.
Press to show DIVE LOG display.
Press to show LOG DATA ERASURE display.
Press to return to DIVE LOG display.
and Press and hold at the same time.
Flashing quickly.
* “LoG-CLE” flashes quickly and then stops flashing after a
few seconds, indicating that the entire log data has been
erased from memory.
No log data is
stored in
memory.
The watch uses an algorithm developed by
Mr. Randy Bohrer, one of the most
distinguished scientists in this field, which
expands upon the theories of the so-called
Swiss model.
Algorithm
De-
compression
diving
The watch is intended for use in no-
decompression diving (diving which allows
you to make a direct, continuous ascent to
the surface). Anticipating emergencies, it
provides information for decompression
diving.
* Decompression diving refers to diving which
requires stops at specified depths during
ascent, due to an impermissible amount of
nitrogen having accumulated in the diver’s
body.
Remains displayed.
Flashing “LoG-
CLE” appears.
HOW TO USE DIVE COMPUTER FUNCTIONS
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Seiko DH33 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Seiko DH33 in the language / languages: English as an attachment in your email.

The manual is 0,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Seiko DH33

Seiko DH33 User Manual - German - 14 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info