IMPORTANT REMARK:
The motor is automatically switched off in the event of
an overload. The motor can be switched on again after a
cooling down period that can vary.
DEFECTIVE ELECTRICAL CONNECTION CABLES
Electrical connection cables often suffer insulation dam-
age.
Possible causes are:
Pinch points when connection cables are run through •
window or door gaps.
Kinks resulting from incorrect attachment or laying of •
the connection cable.
Cuts resulting from running over the connecting ca-•
ble.
Insulation damage resulting from forcefully pulling out •
of the wall socket.
Cracks through aging of insulation.•
Such defective electrical connection cables must not be
used as the insulation damage makes them extremely
hazardous.
Check electrical connection cables regularly for damage.
Make sure the cable is disconnected from the mains
when checking.
Electrical connection cables must comply with the regu-
lations applicable in your country.
SINGLE-PHASE MOTOR
The mains voltage must coincide with the voltage •
specified on the motor’s rating plate.
Extension cables up to a length of 25 m must have a •
cross-section of 1.5 mm2, and beyond 25 m at least
2.5 mm2.
The connection to the mains must be protected with a •
16 A slow-acting fuse.
Only a qualified electrician is permitted to connect the
machine and complete repairs on its electrical equip-
ment.
In the event of enquiries please specify the following
data:
Motor manufacturer•
Type of current of the motor•
Data recorded on the machine’s rating plate•
Data recorded on the switch’s rating plate•
If a motor has to be returned, it must always be dis-
patched with the complete driving unit and switch.
Maintenance
Overhauls, maintenance work, cleaning, as well as the •
elimination of any malfunctions must only be under-
taken after turning off the motor.
All protective and safety equipment must be rein-•
Fig. 5
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach WL05 Woodster at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach WL05 Woodster in the language / languages: English, German, Dutch, French, Italian as an attachment in your email.

The manual is 5.87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info