Mains Connection of the Machine
Check the mains connecting lines. Do not use defective
lines. See electrical connection.
Pay attention to the direction of rotation of the motor
and the tools. See electrical connection.
Installations, repair, and maintenance work relating
to the electric installation may only be performed by
specialists.
Turn off the machine before you repair failures.
Disconnect the mains plug.
Turn off the motor when you leave the workplace.
Disconnect the mains plug.
Disconnect the machine from any external energy supply
also in case of only moving the machine to another,
nearby location! Properly reconnect the machine to the
mains before you turn it on again!
Setup and Adjustment of the Machine
• Only perform retooling, measuring, and cleaning work
when the motor is turned off. Disconnect the mains
plug, and wait until the rotating tool stands still.
All protection and safety devices must be immediately
reinstalled once the repair and maintenance work is
completed.
Proper Use
The grinding machine has been exclusively designed for
grinding steel using the offered tool (no hard alloy).
The machine meets the currently valid EU machine
directive.
The machine has been designed for a one-shift operation,
operating factor S1/100 %.
Observe all safety instructions and warnings on the
device.
Make sure that all safety instructions and warnings on
the machine always are in a readable state.
Only use the machine if it is in a technically faultless
state. Pay attention to the intended use, the safety and
dangers and comply with the operating instructions!
Immediately repair (or have repair) failures which may
affect the safety.
The safety, working, and maintenance instructions and
the dimensions set forth in the specifications must be
observed.
The applicable regulations for the prevention of
accidents and other, generally recognized safety rules
must be observed.
The machine may only be used, maintained or
repaired by trained persons who are familiar with the
machine and have been informed about the dangers.
Unauthorized modifications of the machine exclude a
liability of the manufacturer for damages resulting from
the modifications.
The machine may only be used with original accessories
and original tools of the manufacturer.
• Any other use is considered to be not intended. The
manufacturer excludes any liability for resulting
damages, the risk is exclusively borne by the user.
for use in commercial, trade or industrial applications.
Our warranty will be voided if the equipment is used
in commercial, trade or industrial businesses or for
equivalent purposes.
Residual Risks
The machine has been constructed according to the state
of the art and the recognized safety rules. Nevertheless,
single residual risks may occur during the operation.
The rotating grinding wheel may cause injuries of fingers
and hands.
Danger caused by electric current if inappropriate
electrical connecting lines are used.
Furthermore, non obvious residual risks may exist in
spite of all measures taken.
Residual risks can be minimized by carefully observing
the safety instructions and the intended use as well as
the entire operating instructions.
Assembly
Assemble grinding stone (A) and the star knob (B) as
shown in fig. 1.
Then place the work piece surface (C) into the bracing
element and secure it, using the help of the star knobs
(see fig. 1)
The water tank should be hooked into its port (D) (see fig.
5).
Installation and Adjustment
Please make sure that your grinding machine is installed
in an upright and stable manner on a firm ground with
sufficient illumination.
The machine has no front or rear side. You can alternatively
grind with or against the direction of rotation.
Electrical Connection
The installed electric motor is connected and is ready to
work.
The connection complies with the relevant VDE and DIN
regulations.
The connection to the mains supply on the customer side and
the used extension line must meet these regulations or the
provisions of the local power supply company.
Defective Electric Connection Lines
Often, insulation damages occur on electrical connection
lines.
The possible causes are:
Drag marks if connection lines are led through window or
door clearances. .
Kinks due to improper attachment or routing of the
connection line.
Cuts caused by running over the connection line.
• Insulation damages caused by pulling the connection
line out of the wall socket.
• Fissures caused by the aging of the insulation. Such
defective electrical connection lines must not be used
and are, due to the insulation damages, life threatening!
Regularly check the electrical connection lines for
damages. Please make sure that the connection lines are
disconnected from the mains supply during the check.
Electrical connection lines must meet the applicable VDE
and DIN regulations and the provisions of the local power
supply company. Only use connection lines labeled with
H07 RN. The labeling of the connection cable with the
type specification is required.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach TIGER 2500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach TIGER 2500 in the language / languages: English, German, Dutch, Danish, French, Italian, Spanish, Finnish as an attachment in your email.

The manual is 4.68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info