4. Never operate the machine in non ventilated
rooms or in a highly inammable environment.
If you intend to operate the machine in rooms with
good ventilation, the exhaust gases must be chan-
nelled directly outdoors through an exhaust hose.
m Attention! Toxic exhaust gases can escape
despite the exhaust hose. Due to the re hazard,
never direct the exhaust hose towards inamma-
ble materials.
5. m Risk of explosion!
Never operate the machine in rooms with com-
bustible materials.
6. The speed preset by the manufacturer is not al-
lowed to be changed. The machine or connected
equipment may be damaged.
7. Place the generator at least 1m away from walls
and equipment connected to them.
8. Place the generator in a secure, level position.
Do not turn, tip or change the generator’s position
while it is working.
9. Never touch the generator with wet hands.
10. Guard against electric danger.
11. When working outdoors, use only extension ca-
bles that are approved for outdoor use and which
are marked accordingly (H07RN).
12. The overall length of the extension cables used is
not allowed to exceed 1,5 mm2 for 50 m and 2,5
mm2 for 100 m.
13. Repairs and adjustment work may only be carried
out by authorized trained personnel.
14. Do not touch any mechanically driven or hot parts.
Do not remove the safety guards.
15. The values quoted in the technical data under
sound power level (LWA) and sound pressure
level (LpA) are emission values and not necessar-
ily reliable workplace values. As there is a cor-
relation between emission and immission levels,
the values cannot be taken to reliably determine
the possible need for additional precautions.
Factors inuencing the current immission level
of the user/operator include the properties of
the work area, other sound sources etc., e.g. the
number of machines and other neighboring pro-
cesses, and the time span over which the user/
operator is subjected to the noise. Also, the per-
mitted immission level can vary from country to
country. Nevertheless, this information makes it
possible for the user to be able to make a better
assessment of the dangers and risks involved.
16. Never use a faulty or damaged electrical equip-
ment (this also applies to extension cables and
plug connections).
17. Never put any items into the ventilation openings.
This applies even when the generator is switched
off. Non-observance may lead to injury, or dam-
age to the generator.
6. Work in full consciousness
Do not work with the device when you are under
the inuence of alcohol, drugs, medication or
other substances which might compromise the
vision, dexterity and judgment.
7. Use the device for its prescribed purpose
Any other use than intended is deemed to be a
case of misuse.
Safety notices for handling ammable fuels
1. WARNING!: Petrol is highly ammable:
2. Store fuel in containers specically designed for
this purpose
3. Rell the gasoline tank only outdoors and do not
smoke meanwhile.
4. Add fuel before starting the engine. Never remove
the cap of fuel tank or add petrol while the engine
is running or when the engine is hot.
5. If petrol is spilled, do not attempt to start the en-
gine but move the machine away from the area of
spillage and avoid creating any source of ignition
until petrol vapours have dissipated. Replace all
fuel tank and container caps securely.
Adding fuel
Always switch off the engine before refuelling.
m Attention! Always open the fuel ller cap care-
fully to decompose slowly the excess pressure.
Whilst working with the machine high temperatures
can attain on the case. Allow the engine to cool be-
fore refuelling.
m Attention! In case of insufcient cooling of the
machine the fuel may ignite and lead to serious
burns during refueling.
Make sure not to ll the tank with too much fuel. Im-
mediately remove the fuel and clean the machine
when spilling fuel.
Always close the screw plug on the fuel tank in or-
der to avoid loosening which may occure by vibra-
tions when using the machine.
m DANGER
Never refuel the engine nearby open ames.
Additional safety instructions while hand-ling with
combustion engines
m DANGER
Combustion engines constitute a special danger dur-
ing operation and refuelling. Always read and note
the warnings. Failure to do so can lead to serious or
even deadly injuries.
1. No changes may be made to the generator.
2. m Attention! Danger of poisoning, Emissions,
fuels and lubricants are toxic. Emissions shall not
be inhalated.
3. m Attention! Risk of burns. Do not touch the ex-
haust system or drive unit.
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach SG3400i at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach SG3400i in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 11.37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info