6. Technical Data
AC motor 220-240 V~ 50Hz
performance 2000 Watt
operating mode S6 25%*
Idle speed 5000 min-1
Hard-metal blade ø 250 x ø 30 x 2,8 mm
Number of teeth 24
Thickness riving knife 2 mm
table size 940 x 642 mm
Cutting height max. 90° 85 mm
Cutting height max. 45° 65 mm
height adjustment 0 - 85 mm
saw blade swivel 0 - 45°
suction port ø 35 mm
weight 20,0 kg
* operating mode S6 25%: Continuous operation with in-
termittent loading (playing time 10 min).
Engine protection of to hot warming up:
It´s allowed to run the engine with nominal power maximum
25% of playing time. After this the machine must run 75% of
playing time steadily without load.
Noise values
The total noise values determined in accordance with
EN 61029.
sound pressure level LpA 91,0 dB(A)
uncertainty KpA 3 dB
sound power level LWA 104,0 dB(A)
uncertainty KWA 3 dB
Wear hearing protection.
The effects of noise can cause a loss of hearing. Total
vibration values (vector sum - three directions) deter-
mined in accordance with EN 61029.
7. Before starting the equipment
The equipment must be set up where it can stand
securely.
All covers and safety devices have to be properly t-
ted before the equipment is switched on.
It must be possible for the blade to run freely.
When working with wood that has been processed
before, watch out for foreign bodies such as nails or
screws, etc.
Before you press the ON/OFF switch check that the
saw blade is tted correctly. Moving parts must run
smoothly.
Before you connect the equipment to the power sup-
ply make sure the data on the rating plate are dentical
to the mains data.
Connect the machine to a properly installed protec-
tive contact socket, with at least 16A circuit breaker.
Warning! This electric tool generates an electromag-
netic eld during operation. This eld can impair active
or passive medical implants under certain conditions. In
order to prevent the risk of serious or deadly injuries, we
recommend that persons with medical implants consult
with their physician and the manufacturer of the medical
implant prior to operating the electric tool.
SAFETY INSTRUCTIONS FOR THE HANDLING OF
SAW BLADES
1 Only use insertion tools if you have mastered their
use.
2 Observe the maximum speed. The maximum
speed specied on the insertion tool may not be
exceeded. If specied, observe the speed range.
3 Observe the motor / saw blade direction of rota-
tion.
4 Do not use any insertion tools with cracks. Sort out
cracked insertion tools. Repairs are not permitted.
5 Clean grease, oil and water off of the clamping
surfaces.
6 Do not use any loose reducing rings or bushes for
the reducing of holes on saw blades.
7 Make sure that xed reducer rings for securing the
insertion tool have the same diameter and have at
least 1/3 of the cutting diameter.
8 Make sure that xed reducer rings are parallel to
each other.
9 Handle insertion tool with caution. They are ideally
stored in the originally package or special contain-
ers. Wear protective gloves in order to improve
grip and to further reduce the risk of injury.
10 Prior to the use of insertion tools, make sure that
all protective devices are properly fastened.
11 Prior to use, make sure that the insertion tool
meets the technical requirements of this electric
tool and is properly fastened.
12 Only use the supplied saw blade for sawing opera-
tions in wood, materials similar to wood, plastics
and non-ferrous metals (except for magnesium and
alloys containing magnesium).
Residual risks
The machine has been built according to the state of
the art and the recognised technical safety require-
ments. However, individual residual risks can arise
during operation.
Health hazard due to electrical power, with the use of
improper electrical connection cables.
Furthermore, despite all precautions having been met,
some non-obvious residual risks may still remain.
Residual risks can be minimised if the „safety instruc-
tions“ and the „Proper use“ are observed along with
the whole of the operating instructions.
Do not load the machine unnecessarily: excessive
pressure when sawing will quickly damage the saw
blade, which results in reduced output of the machine
in the processing and in cut precision.
When cutting plastic material, please always use
clamps: the parts which should be cut must always
be xed between the clamps.
Avoid accidental starting of the machine: the oper-
ating button may not be pressed when inserting the
plug in an outlet.
Use the tool that is recommended in this manual. In
doing so, your saw provides optimal performance.
Hands may never enter the processing zone when the
machine is in operation. Release the handle button
and switch off the machine prior to any operations.
Prior to any adjustment, maintenance or service work
disconnect the mains power plug!
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach HS100S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach HS100S in the language / languages: English, German, Polish as an attachment in your email.

The manual is 5.78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info