Switch ON / switch OFF the laser (Fig. 6)
To switch on: Move the ON/OFF (33) switch of the
laser (34) to the “1” position. A laser line is projected
onto the material you wish to process, providing an
exact guide for the cut.
To switch off: Move the ON/OFF switch of the laser
to the “0” position.
Adjusting the laser (Fig. 7)
If the laser (31) ceases to indicate the correct cutting
line, you can readjust the laser. To do so, open the
screws (32) and set the laser by moving sideways to
that the laser beam strikes the teeth of the saw blade
(5).
13. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customer‘s mains connection as well as
the extension cable used must also comply with
these regulations.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the
motor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
Passage points, where connection cables are
passed through windows or doors.
Kinks where the connection cable has been im-
properly fastened or routed.
Places where the connection cables have been cut
due to being driven over.
Insulation damage due to being ripped out of the
wall outlet.
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H 07 RN.
The printing of the type designation on the connec-
tion cable is mandatory.
AC motor
The mains voltage must be 230 V~
Extension cables up to 25 m long must have a
cross-section of 1.5 mm2.
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
Type of current for the motor
Machine data - type plate
Machine data - type plate
14. Accessories
SAW DUST EXTRACTION
The mitre saw is equipped with an extraction port to
which an extraction system can be connected. Alter-
natively, a dust bag can also be attached.
The hose of the extraction system is fastened on the
extraction port with a clamp. We recommend empty-
ing the bag or container from time to time and clean-
ing the lter.
The air speed of the suction system must be at least
30 metres per second.
15. Maintenance
If personnel qualied for unusual maintenance
tasks or repairs must be obtained during of af-
ter the warranty period, please always contact a
service point recommended by us or contact the
manufacturer.
Only perform repair, maintenance and cleaning
work as well as the correction of malfunctions with
the drive switched off as a basic rule.
All protective and safety equipment must be reas-
sembled immediately after repair, maintenance is
completed.
NORMAL SERVICE TASKS
Normal service tasks can also be performed by un-
trained personnel and are all described in the pre-
ceding sections and in this chapter.
The mitre saw must not be lubricated, because it
always cuts dry surfaces; all moving machine parts
are self-lubricating.
In the event of service work, personal protective
equipment must always be work (protective gog-
gles and gloves).
Remove saw dust and chips regularly by cleaning
the cutting zone and support surfaces.
We recommend using a suction tool or brush.
ATTENTION: Do not use compressed air!
Check the saw blade from time to time: If problems
arise with the blade, it must be ground by a specialist
or replaced, depending on the condition.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach HM80L at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach HM80L in the language / languages: All languages as an attachment in your email.

The manual is 11.77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info