22 | GB
13. Storage
Store the device and its accessories in a dark, dry
and frost-proof place that is inaccessible to children.
The optimum storage temperature is between 5 and

Cover the electrical tool in order to protect it from
dust and moisture.
Store the operating manual with the electrical tool.
14. Maintenance
Attention!
Pull out the power plug before carrying out any main-
tenance work on the equipment.
When must the oil be changed?
First oil change after 50 operating hours, then every
500 operating hours.
Oil change (Fig. 12)
Completely retract the splitting column.
Put a container with a volume of at least 6 litres
under the splitter.
Release the oil dipstick 6.
Open the oil drain plug 12a under the oil tank so the

Afterwards, close the oil drain plug 12a again.
Remove the ventilation cap, pour in 4 litres of fresh
hydraulic oil using a clean funnel.
Screw the oil dipstick in again.
Dispose of the used oil in a correct manner at a
public collection facility. It is prohibited to drop
old oil on the ground or to mix it with waste.
We recommend oil from the HLP 32 range.
Splitting spar
Before use, the spar of the splitter must be slightly

hours. Slightly apply grease of oil spray. The spar
may never run dry.
Hydraulic system
The hydraulic unit is a closed system with oil tank, oil
pump and control valve.
The system is complete when the machine is deliv-
ered, and may not be changed or manipulated.
Connections and repairs
Connections and repairs of electrical equipment may
only be carried out by an electrician.
This may have the following causes:
Passage points, where connection cables are
passed through windows or doors.
Kinks where the connection cable has been im-
properly fastened or routed.
Places where the connection cables have been cut
due to being driven over.
Insulation damage due to being ripped out of the
wall outlet.
Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H07RN“.
The printing of the type designation on the connec-
tion cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of 16A (C) or 16A (K) for machines with a high
starting current (starting from 3000 watts)!
AC motor 230 V/ 50 Hz
Mains voltage 230 Volt / 50 Hz.
The mains connection and the extension cable have
to be three-core cables = P + N + SL. - (1/N/PE).
Extension cables must have a minimum cross-section
of 1.5 mm². Mains fuse protection is 16 A maximum.
11. Cleaning
Attention!
Pull out the power plug before carrying out any clean-
ing work on the equipment.
We recommend that you clean the equipment imme-
diately after you use it.
Clean the equipment regularly with a damp cloth and
some soft soap. Do not use cleaning agents or sol-
vents; these may be aggressive to the plastic parts in
the equipment. Ensure that no water can get into the
interior of the equipment.
12. Transport
For transport, the splitting knife A must be completely
moved down. Slightly tilt the log splitter with handle B
on the splitting column until the machine is inclined on
the wheels and can be moved. (Fig 11)
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Scheppach HL810 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Scheppach HL810 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 3.75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info